Thermal performance of non air-conditioned buildings with vaulted roofs in comparison with flat roofs

نویسندگان

  • Runsheng Tang
  • I. A. Meir
  • Tong Wu
چکیده

Vaulted or domed roofs have been frequently adopted by builders and architects throughout the Middle East and other hot dry areas. However, the thermal performance of such buildings under hot dry climatic conditions has rarely been quantitatively studied. In this paper, a detailed finite element model for the investigation of the thermal performance of non air-conditioned buildings with vaulted roofs (VR) is suggested based on two-dimensional unsteady heat transfer in such roofs and solar geometry. This model allows a comparison of the thermal performance of non air-conditioned buildings with a VR and a flat roof (FR) under different climatic conditions. Results obtained by numerical calculation show that, irrespective of building type the VRs are applied to, buildings with a VR have lower indoor temperatures as compared to those with a FR. The reason is that such roofs dissipate more heat than a FR does by convection and thermal radiation at night due to the enlarged curved surfaces. This implies that such roof forms are suitable for buildings located in hot dry regions but not for those located in hot humid areas, and reasonably explains why curved roofs have been extensively adopted by builders and architects in the hot dry areas in the past. However, with the decrease in the half rim angle of a VR, the difference of indoor thermal condition between a VR and a FR building becomes small and insignificant. Results also indicate that the indoor air temperature is slightly influenced by the half rim angle y0 and the orientation fv of the VR. To be effective to create a favorable thermal condition inside buildings with a VR under hot dry climatic conditions, the half rim angle of a VR should be y04501, instead of y0o50 ; which is the optimal half rim angle of a VR of air-conditioned buildings, as found by the present authors in a previous study. r 2005 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal analysis of vaulted roofs

In hot arid regions, cooling buildings by passive techniques is very important regarding energy saving and the need to keep clean the environment. In such areas, domed and vaulted roofs are widely used for centuries, such as in the Middle East region and central part of Iran. In this article analysis is made to explore east–west direction of wind flow around north–south vaulted roofs and flat r...

متن کامل

Investigation on thermal behavior of common types of roofs in buildings using computational fluid dynamics method

In this study, the influence of type and structure of different roofing systems were investigated using computational fluid dynamic method. The considered roofing systems include beam and block types (clay brick, light weight concrete block, polystyrene) and Uboot slab which were designed for 6m and 8m span. To simulate the fluid flow and heat transfer, the computational fluid dynamic method wa...

متن کامل

Hydroponics Roofs for Saving Energy of Green Schools in the Cold and Dry climate of Iran: A Comparative Study between Two Broad and Modular Hydroponic Green Roofs

Green schools are a new type of school, in which the use of renewable energy is less than that of conventional schools. In this regard, nowadays, adding green layers to the roof of schools, in addition to increasing the Students' communication with nature, energy saving has improved in these spaces. However, to improve energy saving yield, the priority of these types of roofs in different clima...

متن کامل

An integrated method to valuate the function of green roofs in absorbing air pollutants; Case study: Tehran

Tehran is the capital city of Iran and its inhabitants are suffering from air pollution.Green roofs can be one of the choices to deal with this problem. In this paper, ability ofgreen roofs in absorbing four air pollutants (PM10, SO2, NO2, and CO2) in Tehran wasvaluated. First, the potential of 1 m2 of a hypothetical green roof in Tehran in absorbingPM10 and SO2 during 1 year was estimated usin...

متن کامل

Thermal Performance of Extensive Green Roofs in Cold Climates

Green roof is a specialized roofing system that supports vegetation growth on rooftops. This technology is rapidly gaining popularity in North America as a sustainable design option. Green roofs offer multiple benefits to urban areas such as reduction of heating/cooling needs for the building, urban heat island and stormwater runoff for the region. In this study, the performance of two extensiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016