Simultaneous kinetic-spectrofluorometric determination of levodopa and carbidopa using partial least-squares regression.

نویسندگان

  • Ariana P Pagani
  • Miguel A Cabezón
  • Gabriela A Ibáñez
چکیده

A simple and sensitive methodology for the simultaneous determination of levodopa and carbidopa in pharmaceutical samples is described. The method combines the advantages of fluorescence with partial least-squares (PLS) analysis, and requires no previous separation steps. The developed method is based on the oxidation of levodopa and carbidopa by cerium(IV) in a sulfuric acid medium and monitoring the fluorescence of the formed Ce(III) at lambda(exc) = 255 nm and lambda(em) = 355 nm. PLS uses differences in the reaction rates as a discriminatory parameter, and regresses the data of fluorescence vs. time onto the concentrations of the standards. Eight validation samples and seven commercial tablets were studied, using a nine-sample aqueous calibration set. The analyte recoveries from pharmaceuticals ranged from 98 to 101% for levodopa and from 100 to 108% for carbidopa. The results obtained by the developed method were statistically comparable to those obtained with high-performance liquid chromatography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous spectrophotometric determination of carbidopa and levodopa by partial least squares regression, principal component regression and least squares support vector machine methods

Three chemometric methods; partial least squares regression (PLS), principal component regression (PCR) and least-squares support vector machines (LS-SVM) were applied for simultaneous determination of carbidopa and levodopa in synthetic mixtures and real samples. The simultaneous determination of these drugs is a difficult problem due to spectral interferences. The proposed methods were used f...

متن کامل

Spectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run

A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...

متن کامل

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...

متن کامل

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...

متن کامل

Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 2009