Evaluation of Synthetic Transmit Aperture 3D Acoustic Imaging Using 2D Transmitter Array

نویسندگان

  • Natsuda Laokulrat
  • Yasushige Maeda
  • Masanori Sugimoto
چکیده

The paper describes a 3D acoustic imaging system that uses a 2D receiver array and a 2D transmitter array. For many years, high quality acoustic imaging has been achieved by using synthetic transmit aperture (STA) technique [1][2]. Normally, STA uses an array of receivers and a small number of transmitters to produce an image. However, the conventional arrangement of transmitters in a same horizontal plane or linear array does not provide good signal strength all over scanned target space since directivity of transmitted signals are limited to some particular directions, i.e. directions along the plane of transmitters. As a result, transmitted signals are strong along the plane of transmitters but weak in upper and lower space so it is not suitable for creating 3D images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

2D Transducer Array for High-Speed 3D Imaging System

3D imaging system was developed utilizing a combination of sparse 2D arrays, the synthetic aperture focusing technique, and coded excitation of a solution for high-speed 3D ultrasound imaging, since it could formulate multiple transmitting beams as well as receiving beams with a minimum number of transmissions. A 40 × 40 array of PZT elements was fabricated with a conventional dice-and-fill pro...

متن کامل

Three-dimensional Real-time Synthetic Aperture Imaging Using a Rotating Phased Array Transducer

Current 3D real-time imaging is done either with sparse 2D arrays, or with mechanically moved phased arrays. The former results in a poor resolution and contrast due to a limited amount of elements. The latter has the disadvantage of low frame rates due to the sequential acquisition of the volume line-by-line and plane-by-plane. This paper describes an approach which combines mechanically moved...

متن کامل

TITLE: System Design, Algorithm Development, and Verification for Optoacoustic Molecular Imaging of Protease Expression in Breast Cancer PRINCIPAL INVESTIGATOR:

The goal of this paper is to compare and contrast various image reconstruction algorithms for optoacoustic tomography (OAT) assuming a finite linear aperture of the kind that arises when using a linear-array transducer. Because such transducers generally have tall, narrow elements, they are essentially insensitive to out of plane acoustic waves, and the usually 3D OAT problem reduces to a 2D pr...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Coded Transmission in Synthetic Transmit Aperture Ultrasound Imaging Method

The paper presents the study of synthetic transmit aperture method applying the Golay coded transmission for medical ultrasound imaging. Longer coded excitation allows to increase the total energy of the transmitted signal without increasing the peak pressure. Signal-to-noise ratio and penetration depth are improved maintaining high ultrasound image resolution. In the work the 128-element linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011