Aqueous humor outflow facility by tonography does not change with body position.

نویسندگان

  • Deepan Selvadurai
  • David Hodge
  • Arthur J Sit
چکیده

PURPOSE Intraocular pressure (IOP) varies with body position and previous research has indicated that most, but not all, of the variation in IOP is due to changes in episcleral venous pressure (EVP). Positional changes in other aqueous humor dynamic parameters may contribute to the change in IOP. The purpose of this study was to investigate the variation of aqueous humor outflow facility with body position changes. METHODS Healthy volunteers, aged 24 to 45 years old, were recruited for this study. Constant weight tonography was performed using a modified electronic Schiotz tonometer in two positions: seated position, 70 degrees from horizontal with neck extended until the cornea was level with floor; and supine position. A minimum of 30 minutes was allowed between the two measurements. Tonography data were fitted to second order polynomials and values for the initial steady state IOP and the outflow facility were determined using standard tables and normograms. IOP was measured using pneumatonometry. RESULTS Forty-two eyes from 21 subjects were studied. IOP in the sitting and supine positions were 17.8 +/- 1.7 mm Hg and 19.9 +/- 1.6 mm Hg, respectively, and were significantly different (P < 0.001). The mean outflow facility in the sitting and supine positions were 0.30 +/- 0.31 microL/mL/mm Hg and 0.28 +/- 0.09 microL/mL/mm Hg, respectively, and were not significantly different (P = 0.37). CONCLUSIONS Aqueous humor outflow facility measured with electronic Schiotz tonography does not vary significantly between the supine and sitting positions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental tonography on enucleated human eyes. I. The validity of Grant's tonography formula.

When newer tables for parameters in Grant's formula for tonography are used, one obtains far higher values for the outflow facility than those generally accepted. The aim of this iinvestigation has, therefore, been to test the validity of the tonography formula. The outflow facility determined by constant-rate perfusion in enucleated eyes has been compared with the results of tonography on the ...

متن کامل

Aqueous humor dynamics during the day and night in juvenile and adult rabbits.

PURPOSE To determine the day and night differences in intraocular pressure (IOP), aqueous flow, outflow facility, uveoscleral outflow, and central corneal thickness (CCT) in juvenile and adult rabbits. METHODS Studies were performed on twelve 3-month-old and ten 12-month-old male New Zealand White rabbits. Daytime measurements were made between 9 AM (3 hours after lights on) and 3 PM, and nig...

متن کامل

Eicosanoids as a new class of ocular hypotensive agents. 2. Comparison of the apparent mechanism of the ocular hypotensive effects of A and F type prostaglandins.

It has recently been shown that derived prostaglandins (PGs) of the A and B types are much more potent ocular hypotensive agents than primary PGs of the E, F, or D type. The purpose of this study was to determine whether two representatives of these structurally different PGs, namely PGA2 and PGF2 alpha-1-isopropyl ester (PGF2 alpha IE), reduce intraocular pressure (IOP) of the feline eye by si...

متن کامل

Aqueous humor dynamics during the day and night in volunteers with ocular hypertension.

OBJECTIVE To evaluate the differences in aqueous humor dynamics between nighttime and daytime in participants with ocular hypertension. METHODS Thirty participants (mean [SD] age, 59.2 [11.1] years) with ocular hypertension were enrolled in the study, which included 1 daytime and 1 nighttime visit. During each visit, measurements included central cornea thickness by ultrasound pachymetry, int...

متن کامل

Comparison of perilimbal suction cup analysis and tonography in the diagnosis of glaucoma.

IN the past few years there has been increasing interest in the use of the pressure cup technique for the investigation of aqueous humour dynamics. Rosengren (1956) demonstrated a rise of intra-ocular pressure when a positive pressure was applied to the sclera overlying Schlemm's canal. He suggested that this rise of pressure was due to continued formation and accumulation of aqueous humour, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 3  شماره 

صفحات  -

تاریخ انتشار 2010