This study was performed to develop and evaluate a semi-automatic seed localization algorithm from magnetic resonance (MR) images for interstitial prostate brachytherapy. The computerized tomography (CT) and MR images (3 mm-slice thickness) of six patients who had received real-time MR imaging-guided interstitial prostate brachytherapy were obtained. An automatic seed localization method was performed on CT images to obtain seed coordinates, and an algorithm for seed localization from MR images of the prostate was developed and tested. The resultant seed distributions from MR images were then compared to CT-derived distribution by matching the same seeds and calculating percent volume receiving 100% of the prescribed dose and the extent of the volume in 3-dimensions. The semiautomatic seed localization method made it possible to extract more than 90% of the seeds with either less than 8% of noises or 3% of missing seeds. The mean volume difference obtained from CT and MR receiving 100% of the prescribed dose was less than 3%. The maximum extent of the volume receiving the prescribed dose were 0.3, 0.6, and 0.2 cm in x, y, and z directions, respectively. These results indicate that the algorithm is very useful in identifying seeds from MR image for post-implant dosimety.
منابع مشابه
Using combined x-ray and MR imaging for prostate I-125 post-implant dosimetry: phantom validation and preliminary patient work.
Post-implantation dosimetry is an important element of permanent prostate brachytherapy. This process relies on accurate localization of implanted seeds relative to the surrounding organs. Localization is commonly achieved using CT images, which provide suboptimal prostate delineation. On MR images, conversely, prostate visualization is excellent but seed localization is imprecise due to distor...
متن کاملProstate MRS in the presence of gold seed fiducial markers
MR Spectroscopy (MRS) has great potential for guiding radiotherapy of prostate cancer by identifying bulky and/or high grade tumors suitable for dose escalation (1,2). However, image guided therapy typically employs permanently implanted gold seed fiducial markers (GSFM), which aid in daily prostate localization prior to treatment. The impact of these gold seed markers on the quality of MRS is ...
متن کاملBioevaluation of 125I Ocu-Prosta seeds for application in prostate cancer brachytherapy
BACKGROUND & OBJECTIVES In recent years, brachytherapy involving permanent radioactive seed implantation has emerged as an effective modality for the management of cancer of prostate. 125 I-Ocu-Prosta seeds were indigenously developed and studies were carried out to assess the safety of the indigenously developed 125 I-Ocu-Prosta seeds for treatment of prostate cancer. METHODS Animal experime...
متن کامل[Results of 125-iodine seed implant with preplanning system in 250 patients with prostate cancer].
INTRODUCTION We review the experience with prostate carcinoma patients treated with permanent implants of 125-I seeds and the outcome eight years after the beginning of this technique. MATERIAL AND METHODS From 2002 to 2007 we have performed 250 implants with LDR brachytherapy with RapidStrand(®) and preplanning system. Mean age was 68 (49-78). Mean PSA was 7.32 (2.31 - 14.6). T1-T2a was the ...
متن کاملA comparison of preplan MRI and preplan CT-based prostate volume with intraoperative ultrasound-based prostate volume in real-time permanent brachytherapy
PURPOSE The present study compared the difference between intraoperative transrectal ultrasound (iTRUS)-based prostate volume and preplan computed tomography (CT), preplan magnetic resonance imaging (MRI)-based prostate volume to estimate the number of seeds needed for appropriate dose coverage in permanent brachytherapy for prostate cancer. MATERIALS AND METHODS Between March 2007 and March ...