Telemetric Blood Pressure Assessment in Angiotensin II-Infused ApoE-/- Mice: 28 Day Natural History and Comparison to Tail-Cuff Measurements

نویسندگان

  • Christopher M. Haggerty
  • Andrea C. Mattingly
  • Ming C. Gong
  • Wen Su
  • Alan Daugherty
  • Brandon K. Fornwalt
  • German E. Gonzalez
چکیده

Abdominal aortic aneurysm (AAA) is a disease of the aortic wall, which can progress to catastrophic rupture. Assessment of mechanical characteristics of AAA, such as aortic distensibility, may provide important insights to help identify at-risk patients and understand disease progression. While the majority of studies on this topic have focused on retrospective patient data, recent studies have used mouse models of AAA to prospectively evaluate the evolution of aortic mechanics. Quantification of aortic distensibility requires accurate measurement of arterial blood pressure, particularly pulse pressure, which is challenging to perform accurately in murine models. We hypothesized that volume/pressure tail-cuff measurements of arterial pulse pressure in anesthetized mice would have sufficient accuracy to enable calculations of aortic distensibility with minimal error. Telemetry devices and osmotic mini-pumps filled with saline or angiotensin-II were surgically implanted in male apolipoprotein-E deficient (ApoE(-/-)) mice. Blood pressure in the aortic arch was measured continuously via telemetry. In addition, simultaneous blood pressure measurements with a volume/pressure tail-cuff system were performed under anesthesia at specific intervals to assess agreement between techniques. Compared to controls, mice infused with angiotensin-II had an overall statistically significant increase in systolic pressure, with no overall difference in pulse pressure; however, pulse pressure did increase significantly with time. Systolic measurements agreed well between telemetry and tail-cuff (coefficient of variation = 10%), but agreement of pulse pressure was weak (20%). In fact, group-averaged pulse pressure from telemetry was a better predictor of a subject's pulse pressure on a given day than a simultaneous tail-cuff measurement. Furthermore, these approximations introduced acceptable errors (15.1 ± 12.8%) into the calculation of aortic distensibility. Contrary to our hypothesis, we conclude that tail-cuff measures of arterial pulse pressure have limited accuracy. Future studies of aneurysm mechanics using the ApoE(-/-)/angiotensin-II model would be better in assuming pulse pressure profiles consistent with our telemetry findings instead of attempting to measure pulse pressure in individual mice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tail‐Cuff Technique and Its Influence on Central Blood Pressure in the Mouse

BACKGROUND Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of th...

متن کامل

Angiotensin II Infusion Promotes Abdominal Aortic Aneurysms Independent of Increased Blood Pressure in Hypercholesterolemic Mice

Infusion of angiotensin II (AngII) into hyperlipidemic mice augments atherosclerosis and causes formation of abdominal aortic aneurysms (AAAs). The purpose of this study was to define the contribution of AngII-induced hypertension to these vascular pathologies. Male apolipoprotein E (apoE) and LDL receptor (LDLr) deficient mice were infused with AngII (1,000 ng/kg/min) or norepinephrine (NE; 5....

متن کامل

Impaired Acetylcholine-Induced Endothelium-Dependent Aortic Relaxation by Caveolin-1 in Angiotensin II-Infused Apolipoprotein-E (ApoE−/−) Knockout Mice

OBJECTIVE The angiotensin II (AngII)-infused apolipoprotein E-deficient (ApoE(-/-)) mouse model is widely used to study atherosclerosis and abdominal aortic aneurysm. An increase in blood pressure has been reported in this model however the underlying mechanism has not been fully explored. In this study, we investigated whether vasomotor dysfunction develops in AngII-infused ApoE(-/-) mice and ...

متن کامل

ANG II infusion promotes abdominal aortic aneurysms independent of increased blood pressure in hypercholesterolemic mice.

Infusion of ANG II in hyperlipidemic mice augments atherosclerosis and causes formation of abdominal aortic aneurysms (AAAs). The purpose of this study was to define the contribution of ANG II-induced hypertension to these vascular pathologies. Male apolipoprotein E (apoE)- and LDL receptor (LDLr)-deficient mice were infused with ANG II (1,000 ng.kg(-1).min(-1)) or norepinephrine (NE; 5.6 mg.kg...

متن کامل

Paradoxical regulation of short promoter human renin transgene by angiotensin ii.

We previously reported the generation of transgenic mice containing the entire human renin gene with a 900-bp promoter. To determine whether all the required elements for angiotensin II-mediated suppression of human renin are present in these mice, angiotensin II was chronically infused by means of osmotic minipump at both low and high doses, 200 and 1000 ng/kg per minute, respectively. Blood p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015