Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion

نویسندگان

  • Jordan L Wilson
  • V A Samaranayake
  • Matt A Limmer
  • Joel G Burken
چکیده

Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time- and cost-efficient. Existing VI assessment methods are time- and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman's correlation coefficients (ρ) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (ρ = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Vapor Intrusion from a Subsurface Diesel Plume Using M ultiple Lines of Evidence

Vapor intrusion from affected soils and groundwater into overlying structures has been identified as a potential mechanism for human exposure to volatile organic chemicals (VOCs), including petroleum hydrocarbons. However, in many cases, background concentrations of organic vapors in indoor air, associated with household products, vehicles, or ambient air, can lead to incorrect conclusions rega...

متن کامل

Indoor Air Contamination from Hazardous Waste Sites: Improving the Evidence Base for Decision-Making

At hazardous waste sites, volatile chemicals can migrate through groundwater and soil into buildings, a process known as vapor intrusion. Due to increasing recognition of vapor intrusion as a potential indoor air pollution source, in 2015 the U.S. Environmental Protection Agency (EPA) released a new vapor intrusion guidance document. The guidance specifies two conditions for demonstrating that ...

متن کامل

Assessment of Public Health Risks Associated with Naphthalene Entering Residences and Commercial Space from Vapor Intrusion at MGP Sites

Naphthalene, a constituent of coal tar, is a contaminant frequently found at former manufactured gas plants (MGP). Development at these sites has resulted in residential and commercial areas with potential exposures from vapor intrusion adversely affecting indoor air of residences and buildings. Naphthalene is routinely analyzed in soil vapor intrusion assessments for properties overlying and s...

متن کامل

It Came From Beneath: Detecting and Mitigating Vapor Intrusion

Although indoor air quality has been a topic of intense public health inquiry for many years, it's only been relatively recent that vapor intrusion has been recognized as a source of indoor air contaminants. Today researchers are searching for better ways to measure and control volatile chemicals that can enter buildings from the soil and groundwater beneath them.

متن کامل

Use of CSIA to Distinguish Between Vapor Intrusion and Indoor Sources of VOCs

Indoor sources of volatile organic compounds (VOCs) are ubiquitous, resulting in detectable concentrations in indoor air, often at concentrations above regulatory screening levels. Because of these indoor sources, the detection of a site-related VOC in a potentially affected building at a concentration above the regulatory screening level does not necessarily indicate a vapor intrusion impact. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018