Conscious sedation and pulse oximetry: false alarms?

نویسنده

  • S Wilson
چکیده

The use of pulse oximetry in dental procedures involving sedation and children has been encouraged strongly. Reports have indicated that hemoglobin desaturations are not uncommon when a variety of drugs (including nitrous oxide) and dosages are used. The present study investigated the nature of desaturations in relation to patient activity as a function of a drug combination, single drug dose-response design, and placebo conditions. Twenty-two patients (mean age 29.45 months; range 20-37 months) participated in this two-part study. In part 1, 12 patients received a placebo and a combination of chloral hydrate and hydroxyzine in a crossover, double-blind design. In part 2, 10 patients received a placebo and three doses of chloral hydrate in a double-blind, randomized sequence of four visits involving a dose-response design. During each restorative visit, the peripheral oxygen saturation, expired carbon dioxide, heart and respiratory rates, blood pressure, and frontalis electromyogram of each child was monitored. The overall results of 63 visits indicated that 87-90% of the 235 desaturation episodes were due to patient movement. The clinical implications of the findings are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation of capnography and pulse oximetry as monitors of pediatric patients sedated for dental treatment.

Traditional methods of monitoring sedated pediatric dental patients have major shortcomings. This study evaluated the use of capnography in conjunction with pulse oximetry for monitoring children during conscious sedation for dental treatment. The specific purposes of the study were to determine if capnography would: (1) detect ventilatory changes that subsequently cause an oxyhemoglobin desatu...

متن کامل

Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial

BACKGROUND Diagnostic and interventional procedures are often facilitated by moderate procedure-related sedation. Many studies support the overall safety of this sedation; however, adverse cardiovascular and respiratory events are reported in up to 70% of these procedures, more frequently in very young, very old, or sicker patients. Monitoring with pulse oximetry may underreport hypoventilation...

متن کامل

Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room.

The frequency and nature of spurious pulse oximetry readings were compared using both a conventional pulse oximeter (CPO) and a prototype Masimo signal extraction technology pulse oximeter (Masimo SET). At a university hospital, 50 ASA physical status I-IV adult patients who underwent general or spinal-epidural anesthesia were selected from a group of 250 patients on the basis of high-alarm gen...

متن کامل

A prospective comparison of 3 new-generation pulse oximetry devices during ambulation after open heart surgery.

OBJECTIVE To assess the clinical performance of 3 new-generation pulse-oximetry signal-processing software systems (Philips FAST, Masimo SET, and Nellcor N-3000) during ambulation after open-heart surgery. DESIGN Prospective, convenience sample. SETTING Cardiac surgical progressive care unit in a 629-bed, not-for-profit, tertiary-care teaching hospital. PATIENTS Status post-cardiac-surger...

متن کامل

Capnography compared to pulse oximetry for early detection of respiratory compromise in non-intubated patients undergoing gastrointestinal endoscopy procedures: a systematic review protocol.

REVIEW QUESTION/OBJECTIVE Does the use of capnography versus pulse oximetry increase the early detection of respiratory compromise and improve safety in non-intubated patients undergoing moderate sedation for gastrointestinal endoscopy procedures?Respiratory compromise will be detected by alveolar hypoventilation/hyperventilation (EtCO2 < 35 mmHg/EtCO2 > 50 mmHg), arterial oxygen desaturation (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric dentistry

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 1990