Accuracy of the geometric-mean method for determining spatial resolutions of tracking detectors in the presence of multiple Coulomb scattering
نویسندگان
چکیده
The geometric-mean method is often used to estimate the spatial resolution of a position-sensitive detector probed by tracks. It calculates the resolution solely from measured track data without using a detailed tracking simulation and without considering multiple Coulomb scattering effects. Two separate linear track fits are performed on the same data, one excluding and the other including the hit from the probed detector. The geometric mean of the widths of the corresponding exclusive and inclusive residual distributions for the probed detector is then taken as a measure of the intrinsic spatial resolution of the probed detector: σ = √ σex · σin. The validity of this method is examined for a range of resolutions with a stand-alone Geant4 Monte Carlo simulation that specifically takes multiple Coulomb scattering in the tracking detector materials into account. Using simulated as well as actual tracking data from a representative beam test scenario, we find that the geometric-mean method gives systematically inaccurate spatial resolution results. Good resolutions are estimated as poor and vice versa. The more the resolutions of reference detectors and probed detector differ, the larger the systematic bias. An attempt to correct this inaccuracy by statistically subtracting multiple-scattering effects from geometric-mean results leads to resolutions that are typically too optimistic by 10-50%. This supports an earlier critique of this method based on simulation studies that did not take multiple scattering into account.
منابع مشابه
High Energy Muon Momentum Estimation from Multiple Coulomb Scattering in Dense Detectors
A method is described for estimating muon track momentum from the distribution of hits along tracks in dense calorimeters due to multiple Coulomb scattering (MCS). The method requires only well-aligned conventional drift chambers or similar tracking devices and can be implemented with or without a magnetic field present. Neutrino experiments can use this technique to increase acceptance for lar...
متن کاملDetermining the accuracy of measuring the thickness of steel plates using Compton scattering method
When there is limitation access to one side of the structure in industry, one of the best methods for thickness measurements is the Compton scattering. In this paper, due to the statistical behavior of dispersed beam counting, we discuss the accuracy of the measurement for steel thickness. Using the experimental method and comparing it with MCNP simulation code, the accuracy is obtained less th...
متن کاملThe Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study
Introduction: In this study, we utilized the MCNP4C Monte Carlo code to quantitatively evaluate the influence of crystal size and material on intercrystal scatter and parallax effects. Materials and Methods: For each of the 5 selected crystals (BGO, LSO, LYSO, LuAP, GSO), transport of 511 keV photons originating from a point source and incident on the central cry...
متن کاملDiagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts
Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...
متن کاملInvestigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]
By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...
متن کامل