Anaerobic Capacityestimated in A Single Supramaximal Test in Cycling: Validity and Reliability Analysis
نویسندگان
چکیده
The aim was to verify the validity (i.e., study A) and reliability (i.e., study B) of the alternative maximal accumulated oxygen deficit determined using onlya supramaximal effort (MAODALT)to estimate anaerobic capacity [i.e., estimated by the gold standard maximal accumulated oxygen deficit method (MAOD)] during cycling. In study A, the effects of supramaximal intensities on MAODALT and the comparison with the MAOD were investigated in fourteen active subjects (26 ± 6 years). In study B, the test-retest reliability was investigated, where fourteen male amateur cyclists (29 ± 5 years) performed the MAODALT twice at 115% of the intensity associated to maximal oxygen uptake (). MAODALT determined at 130 and 150% of was lower than MAOD (p ≤ 0.048), but no differences between MAODALT determined at 100, 105, 110, 115, 120 and 140% of (3.58 ± 0.53L; 3.58 ± 0.59L; 3.53 ± 0.52L; 3.48 ± 0.72L; 3.52 ± 0.61L and 3.46 ± 0.69L, respectively) with MAOD (3.99 ± 0.64L). The MAODALT determined from the intensities between 110 and 120% of presented the better agreement and concordance with MAOD. In the test-retest, the MAODALT was not different (p > 0.05), showed high reproducibility when expressed in absolute values (ICC = 0.96, p < 0.01), and a good level of agreement in the Bland-Altman plot analysis (mean differences ± CI95%:-0.16 ± 0.53L). Thus, the MAODALT seems to be valid and reliable to assess anaerobic capacity in cycling.
منابع مشابه
The effect of twelve session of high intensity cycle training with blood flow restriction on aerobic and anaerobic performance of active men
The purpos of this study was to determine the effect of twelve session of high intensity cycle training with blood flow restriction on aerobic and anaerobic performance of active student men. To this purpose, 24 valentear active students men from physical eduction faculty of kharazmi university aged 19-23 years old, students (mean ± SD weight: 67.89±6 kg, height: 173.92±5.41cm, and BMI: 22.7±...
متن کاملReverse lactate threshold: a novel single-session approach to reliable high-resolution estimation of the anaerobic threshold.
The multisession maximal lactate steady-state (MLSS) test is the gold standard for anaerobic threshold (AnT) estimation. However, it is highly impractical, requires high fitness level, and suffers additional shortcomings. Existing single-session AnT-estimating tests are of compromised validity, reliability, and resolution. The presented reverse lactate threshold test (RLT) is a single-session, ...
متن کاملDesigning a specific upper body anaerobic power test for wrestling
Abstract The aim of this study was designing a specific upper body anaerobic power test for wrestlers and determining validity, reliability and objectivity of the designed test. In order to assess the anaerobic power of wrestlers on the basis of upper body Wingate test, Twenty two wrestlers (age=23/40±3/20 year, height=173/13±6/97 cm, weight=74/55±3/88 kg) of Tehran wrestling team (most of the...
متن کاملMAOD Determined in a Single Supramaximal Test: a Study on the Reliability and Effects of Supramaximal Intensities.
The main barrier to the wide use of maximal accumulated oxygen deficit (MAOD) is the considerable time required to apply several sub- and supra-maximal exercise sessions. The main question of this study was whether the determination of MAOD using a single supramaximal exercise session (MAODALT) is valid and reliable in running. We investigated the effects of the supramaximal exercise intensity ...
متن کاملValidity of the RAST for evaluating anaerobic power performance as compared to Wingate test in cycling athletes
The validity of the Running-based Anaerobic Sprint Test (RAST) was investigated to evaluate the anaerobic power performance in comparison to Wingate test in cycling athletes. Ten mountain-bike male cyclists (28.0±7.3 years) randomly performed Wingate Test and RAST with two trials each. After several anthropometric measurements, peak power (PP), mean power (MP) and fatigue index (FI) for RAST an...
متن کامل