Metal Artifacts in Computed Tomography
نویسنده
چکیده
Karin Andersson (2018): Metal Artifacts in Computed Tomography – impact of reduction methods on image quality and radiotherapy treatment planning. Örebro Studies in Medicine 172. Degradation of image quality by metal artifacts is a common problem in computed tomography (CT) imaging, which can limit the diagnostic value of a CT examination and also introduce inaccuracies in radiotherapy (RT) treatment planning. In recent years, commercial metal artifact reduction (MAR) methods have been launched by several CT vendors. The overall aim of this thesis was to evaluate MAR methods in diagnostic imaging and RT treatment planning. Evaluations of hip prosthesis phantom CT images showed that MAR algorithms in general improved image quality, based on both visual grading analysis and quantitative measures, while the application of virtual monoenergetic reconstructions insufficiently reduced metal artifacts. In some cases additional artifacts were introduced by the MAR algorithms. MAR algorithms were also evaluated in hip prosthesis phantom CT imaging used for proton therapy treatment planning, where improvements in dose calculation accuracy were observed. Studies of Head & Neck (H&N) implant CT images in RT treatment planning were also performed. By visual grading of anatomy visualization with respect to target delineation in dental implant patient images, MAR algorithms were shown to significantly improve image quality. However, only minor effects of H&N implant artifacts on proton dose distributions were seen. The impact might be greater for more severe artifacts than those studied here, and thus further investigations of such cases are needed. In conclusion, MAR algorithms have been shown to enhance image quality for diagnostic applications and to improve anatomy visualization in RT treatment planning. The MAR algorithms led to increased proton dose calculation accuracy in some cases, while in other situations only minor changes were seen.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملEvaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study
Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملMetal Artifact Reduction of Dental Fillings in Head and Neck CT Images
Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...
متن کاملEffect of Exposure Parameters on Metal Artifacts in Cone Beam Computed Tomography
OBJECTIVES The aim of this study was to assess the effect of tube current, kilovoltage peak (kVp), metal type, and the position of metal objects on metal artifacts in cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS Titanium and cobalt-chromium rods were fabricated and placed in a dry human mandible. Samples were scanned using a Promax 3D CBCT unit with different milli-amper...