Appropriateness for Total Joint Replacement: Perspectives of Decision-Makers
نویسندگان
چکیده
BACKGROUND Improving access to total joint replacement (TJR) has been a priority. Without robust mechanisms to ensure appropriateness, these procedures may be overused, incurring substantial costs. In that context, decision-makers are particularly concerned with the appropriateness of TJR. OBJECTIVE While our previous research focused on the appropriateness of TJR from clinical and patient perspectives, this study is aimed at understanding decision-makers' perspectives. METHODS Using a semi-structured guide, we interviewed a convenience sample of decision-makers in four Canadian provinces (Alberta, Manitoba, Nova Scotia and Quebec) between February and March 2013. For the purposes of this study, a decision-maker was defined as a manager, institutional leader or policy maker. RESULTS Fifteen interviews were conducted with decision-makers at ministry (n = 3), regional (n = 6) and institutional levels (n = 8). Decision-makers see themselves as having a key role in the appropriateness discourse, that of optimizing resource allocation and efficient delivery of services for TJR, to improve population outcomes. CONCLUSION The decision-makers' view of appropriateness recognizes the importance of the clinical view, but it offers a very different input into the appropriateness discourse, more closely aligned with appropriateness of setting, which refers to cost-effectiveness considerations.
منابع مشابه
Involvement of Patients in Health Technology Assessment: Further Perspectives for Informing Decision-Makers
Health technology assessment (HTA) is an evaluative process used to inform technology-related policymaking in healthcare. Interest in involving patients in the HTA process is increasing. Patients can provide additional perspectives to those of other groups that are concerned with health technology. Information on patients’ perspectives is preferably obtained through reviews of published studies...
متن کاملAppropriateness of total hip joint replacement.
OBJECTIVE To evaluate the appropriateness of the use of total hip joint replacements. DESIGN Observational study of consecutive patients with a diagnosis of hip osteoarthritis and who had undergone total hip arthroplasty over a 1-year period from seven hospitals. MAIN MEASURES The appropriateness of the use of hip replacement was judged by explicit criteria developed by a panel of experts u...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملSYMPOSIUM: ABJS CARL T. BRIGHTON WORKSHOP ON HEALTH POLICY ISSUES IN ORTHOPAEDIC SURGERY Quality Measurement in Orthopaedics The Purchasers’ View
While all of medicine is under pressure to increase transparency and accountability, joint replacement subspecialists will face special scrutiny. Disclosures of questionable consulting fees, a demographic shift to younger patients, and uncertainty about the marginal benefits of product innovation in a time of great cost pressure invite a serious and progressive response from the profession. Cur...
متن کاملQuality Measurement in Orthopaedics: The Purchasers’ View
While all of medicine is under pressure to increase transparency and accountability, joint replacement subspecialists will face special scrutiny. Disclosures of questionable consulting fees, a demographic shift to younger patients, and uncertainty about the marginal benefits of product innovation in a time of great cost pressure invite a serious and progressive response from the profession. Cur...
متن کامل