Calibration and response of an agarose gel based passive sampler to record short pulses of aquatic organic pollutants.

نویسندگان

  • Angel Belles
  • Claire Alary
  • Yann Aminot
  • James W Readman
  • Christine Franke
چکیده

A passive sampler inspired from previous devices was developed for the integrative sampling of a broad range of contaminants in the water column. Our primary objective was to improve the performance of the device to provide accurate and averaged pollutant water concentrations. For this purpose, an agarose diffusive gel was used as the boundary layer that drives the analyte uptake rate. Contrary to conventional passive samplers, the developed device does not require the sampling rates to be corrected for exposure conditions (e.g. hydrodynamic flow) because the diffusive gel boundary layer selected was sufficiently large to control the pollutant diffusion rate from the aqueous phase. The compounds diffusion coefficients in agarose gel and the gel thickness are the only required data to accurately calculate the time weighted averaged water concentration of pollutants. The performance of the developed sampler was evaluated in the laboratory under two contamination scenarios and in the field in 8 contrasting exposure sites for a selection of 16 emerging pollutants and pesticides. The results show that detection limits of this method are environmentally relevant and allow the determination of the averaged pollutant concentrations. Additionally, the ability of the device to sense very short contamination pulses (5-320min) was evaluated through a theoretical approach and laboratory tests. Results show that the device is suitable for sampling contamination pulses as short as 5min without deviation from the actual average concentrations of pollutants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive sampling of perfluorinated chemicals in water: in-situ calibration.

Perfluorinated chemicals (PFCs) have been recognised as environmental pollutants that require monitoring. A modified polar organic chemical integrative sampler (POCIS) is able to quantify aqueous PFCs. However, with varying external water velocity, PFC sampling rates (Rs) may change, affecting accuracy of derived water concentrations. To facilitate field deployment of this sampler, two methods ...

متن کامل

A New Film-Based Passive Sampler for Moderately Hydrophobic Organic Compounds.

Passive samplers for moderately hydrophobic organic compounds (MHOCs) (i.e., log Kow ranging from 2 to 5) are under-developed compared to those that target polar or strongly hydrophobic compounds. The goal of this study was to identify a suitable polymer and develop a robust and sensitive film-based passive sampler for MHOCs in aquatic systems. Poly(methyl methacrylate) (PMMA) exhibited the hig...

متن کامل

Accelerated solvent extraction (ASE) for purification and extraction of silicone passive samplers used for the monitoring of organic pollutants

Silicone passive samplers have gained an increasing attention as single-phased, practical and robust samplers for monitoring of organic contaminants in the aquatic environment in recent years. However, analytical challenges arise in routine application during the extraction of analytes as silicone oligomers are co-extracted and interfere severely during chemical analyses (e.g. gas chromatograph...

متن کامل

Histopathological response of hepatopancreas and gill in Metopograpsus messor crab exposed to cadmium pollutants

In recent years, monitoring the amount of pollutants in aquatic ecosystems by quantity measures in water, sediment and fish tissue has shifted to the quality measures of pollutant effects on aquatic animals and assessment of aquatic animal health and, ultimately, the ecosystem. This research performed on three replicates has examined the histopathological response of hepatopancreas and gill in ...

متن کامل

Mathematical Modeling of Strong Ground Velocity Pulses using Spectral Decomposition and Forward Directivity Effects

Introduction The nature of near-field earthquake records is very complicated and uncertain. Due to this complexity, the prediction of the real structural responses has become very difficult. Based on the analysis of the physical characteristics of near-field records, it is possible to use the simplified mathematical models. Near-field ground motions which are often associated with a progressiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 165  شماره 

صفحات  -

تاریخ انتشار 2017