Automated segmentation of optic nerve head structures with optical coherence tomography.

نویسندگان

  • Faisal A Almobarak
  • Neil O'Leary
  • Alexandre S C Reis
  • Glen P Sharpe
  • Donna M Hutchison
  • Marcelo T Nicolela
  • Balwantray C Chauhan
چکیده

PURPOSE To quantify and characterize the difference between automated and manual segmentation of optic nerve head structures with spectral-domain optical coherence tomography (SD-OCT). METHODS Optic nerve head radial scans in 107 glaucoma patients and 48 healthy controls were conducted with SD-OCT. Independent segmentations of the internal limiting membrane (ILM) and Bruch's membrane opening (BMO) were performed manually with custom software and with an automated algorithm in each radial scan. The minimum distance between BMO and ILM, termed BMO-minimum rim width (BMO-MRW) was calculated with each segmentation method. Absolute differences between automated and manual segmentations of ILM (ΔILM) and BMO (ΔBMO), and the resulting computation of BMO-MRW (ΔBMO-MRW) were computed. Finally, the relationship between image quality score and ΔILM and ΔBMO was explored. RESULTS The median (interquartile range, IQR) ΔILM was 8.9 (6.5, 13.4) μm in patients and 7.3 (5.3, 9.9) μm in controls. The corresponding values for ΔBMO were 11.5 (6.6, 22.1) μm and 12.4 (6.8, 25.4) μm. Subject-averaged ΔILM was higher in patients than controls (P < 0.01); however, mean ΔBMO was not (P = 0.09). The median (IQR) subject-averaged absolute ΔBMO-MRW was 13.4 (10.6, 16.8) μm in patients and 12.1 (10.0, 16.8) μm in controls and not statistically different (P = 0.21). Mean image quality score was statistically higher in controls than patients (P = 0.03) but not related to subject-averaged ΔILM or ΔBMO. CONCLUSIONS In individual scans, the median difference in ILM and BMO segmentations was <2 and <3 image pixels, respectively. There were no differences between patients and controls in ΔBMO-MRW.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

FloatingCanvas: quantification of 3D retinal structures from spectral-domain optical coherence tomography.

Spectral-domain optical coherence tomography (SD-OCT) provides volumetric images of retinal structures with unprecedented detail. Accurate segmentation algorithms and feature quantification in these images, however, are needed to realize the full potential of SD-OCT. The fully automated segmentation algorithm, FloatingCanvas, serves this purpose and performs a volumetric segmentation of retinal...

متن کامل

DRUNET: A Dilated-Residual U-Net Deep Learning Network to Digitally Stain Optic Nerve Head Tissues in Optical Coherence Tomography Images

Given that the neural and connective tissues of the optic nerve head (ONH) exhibit complex morphological changes with the development and progression of glaucoma, their simultaneous isolation from optical coherence tomography (OCT) images may be of great interest for the clinical diagnosis and management of this pathology. A deep learning algorithm was designed and trained to digitally stain (i...

متن کامل

Automated segmentation of neural canal opening and optic cup in 3D spectral optical coherence tomography volumes of the optic nerve head.

PURPOSE To develop an automated approach for segmenting the neural canal opening (NCO) and cup at the level of the retinal pigment epithelium (RPE)/Bruch's membrane (BM) complex in spectral-domain optical coherence tomography (SD-OCT) volumes. To investigate the correspondence and discrepancy between the NCO-based metrics and the clinical disc margin on fundus photographs of glaucoma subjects. ...

متن کامل

Automated segmentation of optic disc in SD-OCT images and cup-to-disc ratios quantification by patch searching-based neural canal opening detection.

Glaucoma is one of the most common causes of blindness worldwide. Early detection of glaucoma is traditionally based on assessment of the cup-to-disc (C/D) ratio, an important indicator of structural changes to the optic nerve head. Here, we present an automated optic disc segmentation algorithm in 3-D spectral domain optical coherence tomography (SD-OCT) volumes to quantify this ratio. The pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2014