Competitive enzyme-liked immunoassay with use of soluble enzyme/antibody immune complexes for labeling. I. Measurement of human choriogonadotropin.

نویسندگان

  • D E Yorde
  • E A Sasse
  • T Y Wang
  • R O Hussa
  • J C Garancis
چکیده

We described the principle of a new enzyme-immunoassay, competitive enzyme-liked immunoassay (CELIA), for quantitative measurement of soluble antigens and haptens. In the assay, binding of antibody to antigen-immunosorbent is competitively inhibited by the free antigen to be measured. The amount of first antibody bound to the immunosorbent is measured by an enzymatic technique in which a heterologous bridging antibody and a soluble antibody/enzyme immune complex are applied in sequence. The soluble complex we used was rabbit antiperoxidase/horseradish peroxidase. Peroxidase activity is inversely proportional to the concentration in the original sample of the substance to be assayed. The enzyme-linked reagents are potentially widely applicable to any substance to be measured. To demonstrate the feasibility of CELIA, we report a preliminary study of its application to the measurement of human chloriogonadotropin in serum and urine. The assay described for this hormone has a working range of 1 to 50 int. units per milliliter of sample. The technique obviates the disadvantages associated with measurement and handling of radioisotopes in radioimmunoassays and the only major instrumentation required is a centrifuge and a conventional spectrophotometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound-accelerated immunoassay, as exemplified by enzyme immunoassay of choriogonadotropin.

The rate-limiting step in many solid-phase immunoassays is associated with the slow kinetics of binding of macro-molecular antigen and conjugate to the immobilized phase. We demonstrate that the use of ultrasonic energy to enhance mass transport across liquid/solid interfaces can dramatically accelerate antigen binding to immobilized antibodies. We use an ultrasound-accelerated procedure with a...

متن کامل

Simple enzyme immunoassay for the simultaneous measurement of whole choriogonadotropin molecules and free beta-subunits in sera of women with abnormal pregnancies or tumors of the reproductive system.

A multiple enzyme immunoassay (multi-EIA) was developed to quantify whole-molecule human choriogonadotropin (w-hCG) and free hCG beta-subunits (hCG-beta) simultaneously. A clone of a specific monoclonal antibody was coupled to solid phase; two other clones of different monoclonal antibodies were conjugated to horseradish peroxidase (HRP; EC 1.11.1.7) and alkaline phosphatase (AP; EC 3.1.3.1), r...

متن کامل

Enzyme-enhancement immunoassay: a homogeneous assay for polyvalent ligands and antibodies.

A homogeneous enzyme immunoassay for proteins has been developed that avoids the need for a labeled antigen. The technique involves antibody labeled with beta-galactosidase (EC 3.2.1.23), succinylated antibody, and a macromolecular o-nitrophenyl-beta-galactoside substrate. The enzyme-labeled antibody and the succinylated antibody form an immune complex in the presence of sample antigen. An enzy...

متن کامل

Competitive enzyme immunoassay for detection of complement-fixing antibodies in diagnostic virology.

A competitive enzyme immunoassay was developed to detect serum complement-fixing antibodies in virus diseases. This assay utilized conglutinin-covered plastic beads as the solid phase to detect specific antibody-antigen complexes that competed for complement with a probe complex comprised of Escherichia coli beta-galactosidase and its specific antibody. Binding to the solid phase is C3bi mediat...

متن کامل

Reliable measurement of circulating immune complex depends on stable, accurate reference material.

References 1. TheofilopoulosAN, Dixon FJ. The biology and detection of immune complexes [Review]. Adv Immunol 1979;28:89-220. 2. Jordan SC, Gautier E, et al. Quantitation of circulating immune complexes in human serum by the Rsji cell F (ab’)2 anti-C3 micro enzyme immunoassays. J Immunol Methods 1985;83:363-70. 3. Nydegger UE, Svehag SE. Improved standardization in the quantitative estimation o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 8  شماره 

صفحات  -

تاریخ انتشار 1976