Millisecond Fourier-transform infrared difference spectra of bacteriorhodopsin's M412 photoproduct.

نویسندگان

  • M S Braiman
  • P L Ahl
  • K J Rothschild
چکیده

We have obtained room-temperature transient infrared difference spectra of the M412 photoproduct of bacteriorhodopsin (bR) by using a "rapid-sweep" Fourier-transform infrared (FT-IR) technique that permits the collection of an entire spectrum (extending from 1000 to 2000 cm-1 with 8-cm-1 resolution) in 5 ms. These spectra exhibit less than 10(-4) absorbance unit of noise, even utilizing wet samples containing approximately 10 pmol of bR in the measuring beam. The bR----M transient difference spectrum is similar to FT-IR difference spectra previously obtained under conditions where M decay was blocked (low temperature or low humidity). In particular, the transient spectrum exhibits a set of vibrational difference bands that were previously attributed to protonation changes of several tyrosine residues on the basis of isotopic derivative spectra of M at low temperature. Our rapid-sweep FT-IR spectra demonstrate that these tyrosine/tyrosinate bands are also present under more physiological conditions. Despite the overall similarity to the low-temperature and low-humidity spectra, the room-temperature bR----M transient difference spectrum shows significant additional features in the amide I and amide II regions. These features' presence suggests that a small alteration of the protein backbone accompanies M formation under physiological conditions and that this conformational change is inhibited in the absence of liquid water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Resolved Step-Scan Fourier Transform Infrared and Visible Absorption Difference Spectroscopy for the Study of Photosystem I

Step-scan Fourier transform infrared and visible absorption difference spectroscopy, with nanosecond to millisecond time resolution, has been applied to the study of photosystem I particles from photosynthetic oxygen-evolving organisms. In particular, time-reso lved infrared (1800–1200 cm21) and visible (680–850 nm) difference spectra associated with  ash induced oxidation of the primary elect...

متن کامل

Fourier transform infrared spectroscopy study of ligand photodissociation and migration in inducible nitric oxide synthase

Inducible nitric oxide synthase (iNOS) is a homodimeric heme enzyme that catalyzes the formation of nitric oxide (NO) from dioxygen and L-arginine (L-Arg) in a two-step process. The produced NO can either diffuse out of the heme pocket into the surroundings or it can rebind to the heme iron and inhibit enzyme action. Here we have employed Fourier transform infrared (FTIR) photolysis difference ...

متن کامل

Modulation of Fourier Transform Infrared Spectra and Copper Levels by Purslane (Portulaca Oleracea) Against Liver Necrosis Induced by Copper Sulphate

Copper (Cu) is an essential trace element involved in normal reproduction but its over-exposure may produce some detrimental effects. The aim of this study was to investigate the effects of purslane on copper sulfate poisoning on liver structures changes. Twenty eight wistar rats were randomly allocated to four treatment groups. Group I) Control, Group II) Copper sulfate (200 mg/kg bw were appl...

متن کامل

Fourier-Transform Infrared Spectroscopic Comparison of Normal and Malignant Cervical Tissue Cervical Tissue.

Based on the accumulated data, FTIR spectroscopy seems to be a highly sensitive tool in cervical cancer diagnosis. We, therefore, employed this technique in a screening type of research here in Tehran. The purpose of this study was to look for the spectral pattern differences between normal and malignant cervix samples in Iranian women. Through formal and informal announcements, all gynecology ...

متن کامل

Fourier-Transform Infrared Spectroscopic Comparison of Normal and Malignant Cervical Tissue Cervical Tissue.

Based on the accumulated data, FTIR spectroscopy seems to be a highly sensitive tool in cervical cancer diagnosis. We, therefore, employed this technique in a screening type of research here in Tehran. The purpose of this study was to look for the spectral pattern differences between normal and malignant cervix samples in Iranian women. Through formal and informal announcements, all gynecology ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 84 15  شماره 

صفحات  -

تاریخ انتشار 1987