Hemoglobin Rambam (beta69[E13]Gly-->Asp), a pitfall in the assessment of diabetic control: characterization by electrospray mass spectrometry and HPLC.

نویسندگان

  • E Bissé
  • N Zorn
  • A Eigel
  • M Lizama
  • P Huaman-Guillen
  • W März
  • A Van Dorsselaer
  • H Wieland
چکیده

Hemoglobin (Hb) Rambam, or beta69[E13]Gly-->Asp, has been identified in a German woman also suffering from non-insulin-dependent diabetes mellitus and chronic obstructive pulmonary disease. This is the first observation of this Hb variant in a German family thus far. The detailed evaluation of its structure using electrospray mass spectrometry revealed new minor glycohemoglobin components and showed that the attachment of glucose to the beta NH2 terminus occurred at an almost identical rate in both wild-type and mutant beta-chains. However, the introduction of a carboxyl group at beta69 seems to increase the glycation of epsilon-amino groups of lysine residues. The glycemic state in the propositus was well reflected by the total glycohemoglobin concentrations but not by the Hb A1c values, which did not reflect hemoglobin glycation in this patient. This case demonstrates that Hb A1c cannot be used reliably in the management of diabetic patients carrying Hb variants such as Hb Rambam. Functional studies of the whole blood of the heterozygous carrier demonstrated extremely low oxygen affinity, which may have been caused by increased 2,3-diphosphoglycerate related to chronic obstructive pulmonary disease and hyperthyroidism. None of the clinical symptoms could be directly associated to Hb Rambam.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term evaluation of electrospray ionization mass spectrometric analysis of glycated hemoglobin.

BACKGROUND Electrospray ionization mass spectrometry (ESIMS) has been successfully applied to the identification of hemoglobin (Hb) variants and the presence of glucose adducts (mass difference of 162 Da) on the separate Hb alpha and beta chains. To establish the potential of ESIMS as a routine and/or a reference method for the quantification of glycohemoglobin (HbA1c), we carried out a detaile...

متن کامل

Quantitation and characterization of glutathionyl haemoglobin as an oxidative stress marker in chronic renal failure by mass spectrometry.

OBJECTIVES Glutathionyl haemoglobin (GS-Hb) belonging to the class of glutathionylated proteins has been investigated as a possible marker of oxidative stress in different chronic diseases. The purpose of this study was to examine whether glutathionyl haemoglobin can serve as an oxidative stress marker in non-diabetic chronic renal failure patients on different renal replacement therapies (RRT)...

متن کامل

A novel silent posttranslational mechanism converts methionine to aspartate in hemoglobin Bristol (beta 67[E11] Val-Met->Asp).

The first reported case of congenital Heinz body hemolytic anemia was subsequently shown to be caused by an unstable hemoglobin, Hb Bristol [beta 67(E11) Val-Asp]. This has become one of the classic models of an unstable hemoglobin, the hydrophilic aspartate disrupting the hydrophobic heme pocket. We have restudied this original case, who remains clinically well after nearly 50 years of severe ...

متن کامل

Analysis of Oligonucleotides by HPLC-Electrospray Ionization Mass Spectrometry.

A new interface procedure has been developed that allows, for the first time, the high-efficiency analysis of synthetic oligonucleotides up to 75 bases by reversed-phase HPLC and on-line electrospray ionization mass spectrometry. For oligonucleotides up to 30 bases in length, single-base resolution can be obtained with low levels of cation adduct formation in the negative ion electrospray mass ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 10  شماره 

صفحات  -

تاریخ انتشار 1998