Torque history of electrically stimulated human quadriceps: implications for stimulation therapy.

نویسندگان

  • R L Lieber
  • M J Kelly
چکیده

The time course of knee extension torque was measured in human quadriceps muscles during 30 min of transcutaneous neuromuscular electrical stimulation (NMES). Ninety subjects were divided into six experimental groups (n = 15 per group), which received stimulation at one of the following frequency/duty cycle combinations: 10 Hz/50%, 30 Hz/50%, 50 Hz/50%, 10 Hz/70%, 30 Hz/70%, and 50 Hz/70%. Two-way analysis of variance revealed that the magnitude of the relative torque decrease (the percentage of decrease in torque relative to the initial value) was significantly different between frequencies (p < 0.005) and duty cycles (p < 0.02), with no significant interaction (p > 0.6). Increasing either frequency or duty cycle caused a greater decrease in torque. In spite of this result, there was no significant difference between groups in the total activity (torque-time integral) achieved during the 30 min treatment session. The magnitude of this activity corresponded to only about 7-14 maximum voluntary contractions. Finally, the average torque during the treatment session was significantly different among groups (p < 0.001), being greatest for the 50 Hz/50% group and least for the 10 Hz/70% group. Taken together, these data suggest that a smaller number of longer duration contractions produces the greatest muscle tension. They also suggest that the absolute torque levels achieved with NMES are relatively low compared with voluntary muscular activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in quadriceps femoris muscle torque when using a clinical electrical stimulator versus a portable electrical stimulator.

BACKGROUND AND PURPOSE There have been conflicting views and evidence reported in the literature concerning differences in muscle torque-generating capacities between clinical ("plug-in") console devices whose power source is provided by an electrical outlet (60 Hz, alternating current-driven) and portable electrical muscle stimulators (smaller, battery-operated stimulators). The purpose of thi...

متن کامل

Quadriceps femoris muscle resistance to fatigue using an electrically elicited fatigue test following intense endurance exercise training.

BACKGROUND AND PURPOSE Electrical stimulation has been used to assess skeletal muscle resistance to fatigue. The purpose of this study was to test the hypothesis that 12 weeks of intense endurance exercise training on a bicycle ergometer would reduce the percentage of decline in quadriceps femoris muscle torque during an electrically elicited fatigue test. SUBJECTS AND METHODS Eleven nondisab...

متن کامل

Long-term intensive electrically stimulated cycling by spinal cord-injured people: effect on muscle properties and their relation to power output.

Inactivity and muscular adaptations following spinal cord injury (SCI) result in secondary complications such as cardiovascular disease, obesity, and pressure sores. Functional electrically stimulated (FES) cycling can potentially reduce these complications, but previous studies have provided inconsistent results. We studied the effect of intensive long-term FES cycle training on muscle propert...

متن کامل

The Effect of Voluntary and Electrically Stimulated Quadriceps Muscle Fatigue on Postural Control

Purpose: The present study aimed to investigate the effect of voluntary and electrically stimulated quadriceps muscle fatigue on postural control. Methods: Sixteen healthy young males participated in this quasi-experimental study. All subjects performed two fatiguing exercises with equal intensity of isometric maximal voluntary contraction: Voluntary (VOL) and Electrical Stimulation (ES). The ...

متن کامل

Identification of Quadriceps-Shank Dynamics Using Randomized Interpulse Interval Stimulation

Absbuct-Model structures for artificially stimulated paralyzed muscle-limb system dynamics were developed and experimentally evaluated in paraplegic patients. The examined system consisted of the quadriceps, electrically stimulated using surface electrodes, and a freely swinging shank. The interpulse interval of the stimulation sequence was randomized to obtain persistent system excitation. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 1993