Study protocol for the PHANTOM study: prehospital assessment of noninvasive tissue oximetry monitoring

نویسندگان

  • Andrew Weatherall
  • Alan Garner
  • Nigel Lovell
  • Stephen Redmond
  • Anna Lee
  • Justin Skowno
  • Jonathan Egan
چکیده

BACKGROUND Traumatic brain injury is a major cause of mortality and morbidity worldwide. It can be worsened by secondary injury particularly with hypoxia or hypotension. Current prehospital guidelines emphasise regular measurement of peripheral oxygen saturation and blood pressure but there is no monitor in use to provide direct information relating to blood flow or oxygen delivery to the brain tissue. This prospective cohort study will assess the utility of near-infrared spectroscopy monitoring in prehospital medicine in demonstrating injury, pathophysiology and associations with long-term functional outcomes. METHODS/DESIGN A prospective cohort study will be conducted in prehospital services where physician/paramedic teams respond rapidly to patients suffering significant traumatic injuries. A study observer accompanying the clinical team will apply non-invasive near-infrared spectroscopy tissue oximetry using a Nonin EQUANOX 7610 Regional Oximetry monitor (TM Nonin Medical, Inc.). This will be applied to patients with traumatic injuries less than 30 minutes old requiring transport. Measurements will be taken at two sites on the forehead and one on the forearm. Clinical teams will be blinded to all monitoring values. Near-infrared spectroscopy tissue oximetry parameters of oxyhaemoglobin%, deoxyhaemoglobin%, total tissue haemoglobin index and regional oxygen saturation will be recorded. Separate statistical analysis relating to time spent with cerebral regional oxygen saturation values < 45% and time series analysis will be performed to demonstrate associations with acute phase outcomes including injuries seen on cerebral imaging, and long-term functional outcomes measured by Glasgow Outcome Score and Extended Glasgow Outcome Score will then be undertaken. DISCUSSION This prospective cohort study will demonstrate associations evident from the earliest stages of prehospital treatment between near-infrared spectroscopy tissue oximetry values and both acute and long-term outcomes of patients suffering traumatic injuries. This may provide the basis for future interventional studies utilising near-infrared spectroscopy tissue oximetry to guide prehospital trauma care. TRIAL REGISTRATION This trial is registered with the Australian and New Zealand Clinical Trials Registry. The registration number is ACTRN12611001124921 .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse oximetry at the roadside: a study of pulse oximetry in immediate care.

The measurement of tissue oxygen saturation with a pulse oximeter is of proved value in the hospital setting. The development of a portable oximeter has allowed this investigation to be performed during the prehospital phase of a patient's care. Pulse oximetry was performed at the roadside in 25 patients with abnormal trauma scores and found to be of benefit in detecting and monitoring hypoxia ...

متن کامل

Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...

متن کامل

Non-invasive carboxyhemoglobin monitoring: screening emergency medical services patients for carbon monoxide exposure.

INTRODUCTION Carbon monoxide (CO) toxicity is a significant health problem. The use of non-invasive pulse CO-oximetry screening in the emergency department has demonstrated that the rapid screening of numerous individuals for CO toxicity is simple and capable of identifying occult cases of CO toxicity. OBJECTIVE The objective of this study was to extend the use of this handheld device to the ...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose

Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2014