Feasibility of Diffusion Tensor Imaging at 1.5T Using Multi-Band Echo Planar Acquisition

نویسندگان

  • Minoru Mitsuda
  • Yuichi Suzuki
  • Akira Kunimatsu
  • Akihiro Kasahara
  • Yasushi Watanabe
  • Kenji Ino
  • Keiichi Yano
  • Kuni Ohtomo
چکیده

We report that diffusion tensor imaging (DTI) and tractography (DTT) of the pyramidal tracts using multi-band (MB) EPI could be a useful tool with a 1.5T MRI. We compared images using single-band EPI (SB-EPI) and MB-EPI. MB-EPI could reduce the scanning time by about 40%. We demonstrated that it is comparable between image qualities of SB-EPI and MB-EPI using tract-specific analysis and dice coefficients. Therefore, MB-EPI can promote high-speed DTI and DTT in clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging.

BACKGROUND AND PURPOSE Diffusion tensor magnetic resonance imaging (DTI) of the brain is usually acquired with single-shot echo-planar imaging, which is associated with localized signal loss, geometric distortions, and blurring. Parallel imaging can lessen these artifacts by shortening the length of the echo-train acquisition. The self-calibrating parallel acquisition techniques, image domain-b...

متن کامل

Reduction of Aliasing Artifacts in Diffusion-Weighted PROPELLER Imaging

Introduction Diffusion imaging is typically performed in axial planes. This is largely due to its reliance on single-shot echo-planar imaging (EPI) which suffers from increased image distortion in sagittal and coronal planes because of concomitant gradient fields [1-2], especially with strong gradients and/or at relatively low B0-fields (including 1.5T). Diffusion-weighted (DW) imaging in non-a...

متن کامل

In vivo diffusion tensor imaging of rat spinal cord with echo planar imaging.

The in vivo apparent diffusion tensor (ADT) of spinal cord was measured in nine rats at 2.0 T using an interleaved multi-shot echo planar imaging (EPI) diffusion sequence. A technique that combines sliding acquisition and phase correction, based on a calibration scan, to reduce ghosting artifacts in the images introduced by the strong diffusion-sensitizing gradients was described. Two rotationa...

متن کامل

MR diffusion tensor imaging and fiber tracking in spinal cord arteriovenous malformations: a preliminary study.

BACKGROUND AND PURPOSE Diffusion tensor imaging (DTI) of the spinal cord in patients harboring spinal arteriovenous malformations (AVMs) was carried out to evaluate the feasibility of this new technique to determine the displacement of the spinal cord tracts and to correlate morphologic and functional DTI data (fractional anisotropy [FA] and apparent diffusion coefficient [ADC]) with the clinic...

متن کامل

Diffusion tensor imaging of the kidney at 3 Tesla MRI: normative values and repeatability of measurements in healthy volunteers.

PURPOSE To evaluate the feasibility of renal diffusion tensor imaging and determine the normative fractional anisotropy and apparent diffusion coefficient values at 3 Tesla magnetic resonance imaging (MRI) using parallel imaging and free breathing technique. MATERIALS AND METHODS A total of 52 young healthy volunteers with no history of renal disease were included in the study. MRI examinatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017