Comparing Dorsal Tangential and Lateral Views of the Wrist for Detecting Dorsal Screw Penetration after Volar Plating of Distal Radius Fractures
نویسندگان
چکیده
BACKGROUND The dorsal tangential (DT) view has been shown to improve the detection of dorsal screw perforation during volar distal radius fracture fixation. Here we performed a cadaveric imaging survey study to evaluate if the DT view was uniformly beneficial for all screws. METHODS Standardized placement of fixed-angle volar distal radius plates was performed on two cadavers. Fluoroscopic images depicting variable screw perforation of each of the four screw holes on the plate were generated. A 46-image survey was distributed at a large academic medical center. Respondents were asked to answer if the screw was perforating through the dorsal cortex in each image. Statistical analysis was performed using Fisher's exact test. A p value < .05 was considered significant. RESULTS The DT view offered a significantly more reliable determination of dorsal screw penetration than traditional lateral imaging for the radial-most screw at all degrees of perforation and the middle two screws at 2 mm of perforation. Residents and attendings had more accurate screw readings overall using the DT view. CONCLUSIONS The DT view is superior to traditional lateral imaging in the detection of small amounts of dorsal perforation of the radial-most three screws of a fixed-angle volar plate.
منابع مشابه
The Detection of Prominent Hardware in Volar Locked Plating of Distal Radius Fractures: Intraoperative Fluoroscopy Versus Computed Tomography.
OBJECTIVES To assess the utility of the dorsal tangential view (DTV) in detecting intraoperative dorsal screw penetration in distal radius fractures treated with volar locked plating. DESIGN Retrospective cohort study. SETTING Academic level 1 trauma center. PATIENTS/PARTICIPANTS Skeletally mature patients where open reduction internal fixation with volar locked plating was the definitive...
متن کاملUltrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation
BACKGROUND Complications related to extensor tendons have begun to increase with the use of volar plates in the treatment of distal radius fractures. In this study, we aimed to compare four-plane radiography and ultrasonography in the evaluation of dorsal cortex screw penetration following volar plate fixation. METHODS We recruited 47 patients (33 males, 14 females, mean age 37.4 years; range...
متن کاملAnalysis of soft-tissue complications of volar plate fixation for managing distal radius fractures and clinical effect while preserving pronator quadratus.
The aim of the study was to analysis soft-tissue complications of volar plate fixation and it's prevention strategies along with exploring clinical effects of preserving pronator quadratus (PQ) muscle. From February 2011 to February 2013, sixty-five patients with distal radius fracture underwent open reduction and internal fixation with the volar locking palmar plates. The group with preserving...
متن کاملTangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures
BACKGROUND Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, wh...
متن کاملCombined volar and dorsal plating for complex comminuted distal radial fractures.
PURPOSE To review outcomes of combined volar and dorsal locked plating for AO type-C3 complex comminuted distal radial fractures. METHODS Records of 24 patients aged 17 to 77 (mean, 53.3) years who underwent combined volar and dorsal locked plating for AO type-C3 distal radial fractures with volar and dorsal metaphyseal and intra-articular comminution were reviewed. 21 were closed fractures, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017