The long-term cost-effectiveness of fetal monitoring during labour: a comparison of cardiotocography complemented with ST analysis versus cardiotocography alone

نویسندگان

  • E Heintz
  • T-H Brodtkorb
  • N Nelson
  • L-Å Levin
چکیده

OBJECTIVE To assess the cost-effectiveness of the use of cardiotocography (CTG) complemented with fetal electrocardiography and ST analysis compared with the use of CTG alone in term deliveries when a decision has been made to use fetal monitoring with a scalp electrode. DESIGN A cost-effectiveness analysis based on a probabilistic decision model incorporating relevant strategies and lifelong outcomes. SETTING Maternity wards in Sweden. POPULATION Women with term fetuses after a clinical decision had been made to apply a fetal scalp electrode for internal CTG. METHODS A decision model was used to compare the costs and effects of two different treatment strategies. Baseline estimates were derived from the literature. Discounted costs and quality-adjusted life years (QALYs) were simulated over a lifetime horizon using a probabilistic model. MAIN OUTCOME MEASURES QALYs, incremental costs, and cost per QALY gained expressed as incremental cost-effectiveness ratio (ICER). RESULTS The analysis found an incremental effect of 0.005 QALYs for ST analysis compared with CTG; the ST analysis strategy was also moreover associated with a euro56 decrease in costs, thus dominating the CTG strategy. The probability that ST analysis is cost-effective in comparison with CTG is high, irrespective of the willingness-to-pay value for a QALY. CONCLUSIONS Compared with CTG alone, ST analysis is cost-effective when used in term high-risk deliveries in which there is a need for internal fetal monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial.

BACKGROUND Previous studies indicate that analysis of the ST waveform of the fetal electrocardiogram provides information on the fetal response to hypoxia. We did a multicentre randomised controlled trial to test the hypothesis that intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis results in an improved perinatal outcome compared with cardiotocography al...

متن کامل

A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography--a randomised controlled study.

OBJECTIVE To examine whether intrapartum monitoring by means of automatic ST analysis (STAN) of fetal electrocardiography could reduce the rate of neonatal acidemia and the rate of operative intervention during labour, compared with monitoring by means of cardiotocography (CTG). DESIGN Randomised controlled trial. SETTING Labour ward in tertiary-level university hospital. SAMPLE A total o...

متن کامل

A randomised clinical trial on cardiotocography plus fetal blood sampling versus cardiotocography plus ST-analysis of the fetal electrocardiogram (STAN®) for intrapartum monitoring

BACKGROUND Cardiotocography (CTG) is worldwide the method for fetal surveillance during labour. However, CTG alone shows many false positive test results and without fetal blood sampling (FBS), it results in an increase in operative deliveries without improvement of fetal outcome. FBS requires additional expertise, is invasive and has often to be repeated during labour. Two clinical trials have...

متن کامل

Protocol for a randomised controlled trial of fetal scalp blood lactate measurement to reduce caesarean sections during labour: the Flamingo trial [ACTRN12611000172909]

BACKGROUND The rate of caesarean sections around the world is rising each year, reaching epidemic proportions. Although many caesarean sections are performed for concerns about fetal welfare on the basis of abnormal cardiotocography, the majority of babies are shown to be well at birth, meaning that the operation, with its inherent short and long term risks, could have been avoided without comp...

متن کامل

Randomised controlled trial of cardiotocography versus Doppler auscultation of fetal heart at admission in labour in low risk obstetric population.

OBJECTIVE To compare the effect of admission cardiotocography and Doppler auscultation of the fetal heart on neonatal outcome and levels of obstetric intervention in a low risk obstetric population. DESIGN Randomised controlled trial. SETTING Obstetric unit of teaching hospital PARTICIPANTS Pregnant women who had no obstetric complications that warranted continuous monitoring of fetal hea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bjog

دوره 115  شماره 

صفحات  -

تاریخ انتشار 2008