Solubility of root canal sealers: a comparative study.
نویسندگان
چکیده
INTRODUCTION Root canal sealers used in odontological applications are capable of providing an apical seal, thus inhibiting potential bacterial penetration into the periradicular tissues. Since insolubility is the ideal characteristic for a root canal sealer material, in dentistry the sealability of the material depends on its solubility. PURPOSE This study tested the solubility of six different root canal sealers: two ZnOE-based sealers (Endomethasone C and Argoseal), two calcium hydroxide-containing sealers (Bioseal Normal and Acroseal), and two resin-based sealers (AH Plus and MM Seal). METHODS Ten specimens of each material were prepared using stainless steel ring molds with the same internal diameter and the same height in order to obtain similar samples, and immersed in water. Solubility was determined by using sample weight loss (%) after 24 hours and after 2 months. The test was performed according to the International Standards Organization 6876 standard and the American Dental Association specifications No. 30 and No. 57. Data were statistically analyzed with a one-way analysis of variance test (ANOVA). RESULTS The ANOVA test showed significant differences between the various groups. The post-hoc test showed that resin-based root canal sealers had significantly lower solubility percentages than other groups (p<0.05), and showed no difference between them (p>0.05). CONCLUSIONS All the materials fulfilled the requirements of International Standard 6876 and ANSI/ADA specifications demonstrating a weight loss of less than 3%. Under the conditions of the present study, all root canal sealers were of low solubility, but the lowest solubility percentages were recorded in resin-based root canal sealers, which can be considered virtually insoluble, and thanks to this physical property, ideal for use as endodontic sealer.
منابع مشابه
Solubility and pH of bioceramic root canal sealers: A comparative study
Background This study compared the solubility and the pH of different root canal sealers in vitro. Material and Methods BioRoot™RCS, TotalFill BC Sealer, MTA Fillapex, SealapexTM, AH Plus, EasySeal, Pulp Canal Sealer™ and N2 were tested. Similar specimens were prepared using ring molds with an internal diameter of 20 ± 0,1 mm and a height of 1,5 ± 0,1 mm and digitally weighted to register the...
متن کاملMTA-Based Root Canal Sealers
Mineral trioxide aggregate (MTA) has been recommended for pulp capping, pulpotomy, apical barrier formation in teeth with open apexes, repair of root perforation and root canal obturation. Since, its introduction in 1993 by Torabinejad numerous studies have been published regarding various aspects of this material. The aim of this review was to consider MTA as root canal sealer and various labo...
متن کاملCalcium hydroxide-based root canal sealers: a review.
The aim of this review was to consider laboratory experiments and clinical studies of calcium hydroxide-based root canal sealers. An extensive search of the endodontic literature was made to identify publications related to calcium hydroxide-based root canal sealers. The articles were assessed for the outcome of laboratory and clinical studies on their biological properties and physical charact...
متن کاملBioceramic-Based Root Canal Sealers: A Review
Bioceramic-based root canal sealers are considered to be an advantageous technology in endodontics. The aim of this review was to consider laboratory experiments and clinical studies of these sealers. An extensive search of the endodontic literature was made to identify publications related to bioceramic-based root canal sealers. The outcome of laboratory and clinical studies on the biological ...
متن کاملPhysical Properties and Chemical Characterization of Two Experimental Epoxy Resin Root Canal Sealers
INTRODUCTION The aim of this in vitro study was to evaluate the setting time, flow, film thickness, solubility, radiopacity and characterization analysis of three epoxy resin based sealers including two experimental sealers and AH-26. METHODS AND MATERIALS Five samples of each material were evaluated for setting time, flow, film thickness, solubility and radiopacity according to ISO 6876 Stan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of artificial organs
دوره 33 9 شماره
صفحات -
تاریخ انتشار 2010