Determination of Soil Pore Water Salinity Using an FDR Sensor Working at Various Frequencies up to 500 MHz
نویسندگان
چکیده
This paper presents the application of a frequency-domain reflectometry (FDR) sensor designed for soil salinity assessment of sandy mineral soils in a wide range of soil moisture and bulk electrical conductivity, through the determination of soil complex dielectric permittivity spectra in the frequency range 10-500 MHz. The real part of dielectric permittivity was assessed from the 380-440 MHz, while the bulk electrical conductivity was calculated from the 165-325 MHz range. The FDR technique allows determination of bulk electrical conductivity from the imaginary part of the complex dielectric permittivity, without disregarding the dielectric losses. The soil salinity status was determined using the salinity index, defined as a partial derivative of the soil bulk electrical conductivity with respect to the real part of the soil complex dielectric permittivity. The salinity index method enables determining the soil water electrical conductivity value. For the five sandy mineral soils that have been tested, the relationship between bulk electrical conductivity and the real part of dielectric permittivity is essentially linear. As a result, the salinity index method applied for FDR measurements may be adapted to field use after examination of loam and clayey soils.
منابع مشابه
A FDR Sensor for Measuring Complex Soil Dielectric Permittivity in the 10–500 MHz Frequency Range
Mechanical details as well as electrical models of FDR (frequency domain reflectometry) sensors for the measurement of the complex dielectric permittivity of porous materials are presented. The sensors are formed from two stainless steel parallel waveguides of various lengths. Using the data from VNA (vector network analyzer) with the connected FDR sensor and selected models of the applied sens...
متن کاملSimultaneous Monitoring of Soil Water Content and Salinity with a Low-Cost Capacitance-Resistance Probe
Capacitance and resistivity sensors can be used to continuously monitor soil volumetric water content (θ) and pore-water electrical conductivity (EC(p)) with non-destructive methods. However, dielectric readings of capacitance sensors operating at low frequencies are normally biased by high soil electrical conductivity. A procedure to calibrate capacitance-resistance probes in saline conditions...
متن کاملPresentation of a Complex Permittivity-Meter with Applications for Sensing the Moisture and Salinity of a Porous Media
This paper describes a sensor dedicated to measuring the vertical profile of the complex permittivity and the temperature of any medium in which sensor electrodes are inserted. Potential applications are the estimate of the humidity and salinity in a porous medium, such as a soil. It consists of vertically-stacked capacitors along two conductive parallel cylinders of 5 cm in diameter and at a 1...
متن کاملLaboratory Performance of Five Selected Soil Moisture Sensors Applying Factory and Own Calibration Equations for Two Soil Media of Different Bulk Density and Salinity Levels
Non-destructive soil water content determination is a fundamental component for many agricultural and environmental applications. The accuracy and costs of the sensors define the measurement scheme and the ability to fit the natural heterogeneous conditions. The aim of this study was to evaluate five commercially available and relatively cheap sensors usually grouped with impedance and FDR sens...
متن کاملFrequency Dependence of the Complex Permittivity and Its Impact on Dielectric Sensor Calibration in Soils
tiveness of TDR. However, the emergence of low-cost, high-frequency oscillators has led to an increased interThe capacitance (CAP) method and time domain reflectometry est in CAP techniques (e.g., Dean et al., 1987; Evett (TDR) are two popular electromagnetic techniques used to estimate soil water content. However, the frequency dependence of the real and Steiner, 1995; Paltineanu and Starr, 19...
متن کامل