A novel 12-station hip joint simulator with an anatomic position of the prosthesis was designed and built. The motion of the simulator consists of flexion-extension and abduction-adduction. The load is of the double-peak type. The validation test was done with three similar 28 mm CoCr-polyethylene joints in diluted calf serum lubricant for 3.3 x 10(6) cycles. The bearing surfaces of the polyethylene cups were burnished, the CoCr heads were undamaged, the wear particles were in the 0.1-1 microm size range, and the mean wear factor of the polyethylene cups was 5.7 x 10(-7) mm(3)/N m. These essential observations were in good agreement with clinical findings. In addition, three similar 50 mm CoCr/CoCr joints, representing the contemporary large-diameter metal-on-metal articulation were tested. The wear of the CoCr/CoCr joints was calculated from the Co and Cr concentrations of the used lubricant quantified with atomic absorption spectroscopy. The bearing surfaces of the CoCr/CoCr joints showed mild criss-cross scratching only. The average wear factor of polyethylene cups was 275 times that of the CoCr/CoCr joints. The tribological behaviour of the large-dia. CoCr/CoCr appeared to be dominated by fluid film lubrication, as indicated by very low frictional heating and wear, making it tribologically superior to the conventional CoCr/polyethylene, and therefore very interesting clinically. In conclusion, the simulator proved to be a valid, reliable, practical, economical, and easy-to-operate tool for wear studies of various hip replacement designs.
منابع مشابه
Microseparation and stripe wear in alumina-on-alumina hip implants.
The combination of materials that still has highest wear resistance for total hip replacement is ceramic-on-ceramic. However, brittleness is a major concern for ceramics: in vivo and in vitro studies on ceramic hip prostheses correlate microseparation with hip noise, ceramic wear, or ceramic liner damage. Ceramic microseparation can lead to edge load, ceramic head wear, and squeaking. The aim o...
متن کاملپارامترهای آناتومیک مفصل هیپ و ارتباط آنها با پارامترهای فیزیکی بدن
Background and Objective: Arthrosis of the hip joint is one of the most common complications of patients and many efforts have been made to find its etiology. One of the subjects important for researchers is morphologic parameters of the hip joint and its relationship with osteoarthritis of this joint. Since these parameters themselves are affected by physical parameters of the body and the rac...
متن کاملInfluence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings
Hip joint simulators are used extensively for preclinical testing of hip replacements. The variation in simulator design and test conditions used worldwide can affect the tribological performance of polyethylene. The aim of this study was to assess the effects of simulator mechanics and design on the wear and creep of ultra-high-molecular-weight polyethylene. In the first part of this study, an...
متن کاملThe Morphology of Uhmwpe Wear Debris Generated by a Hip Joint Simulator
THE MORPHOLOGY OF UHMWPE WEAR DEBRIS GENERATED BY A HIP JOINT SIMULATOR
متن کاملMotion Simulation of the Hip Joint Using an Opzimized Markers Configuration
INTRODUCTION Simulating joint motion is a prerequisite for any efficient surgical planning system. In this paper, we present a methodology that combines MRI and motion capture systems (Mocap) to simulate and visualize the hip joint motion with an optimized markers configuration. MR images are used to capture the subject’s anatomy as well as the trajectories of the skin markers that are attached...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 219 6 شماره
صفحات -
تاریخ انتشار 2005