First experiences in using a dose control system on a TomoTherapy Hi·Art II

نویسندگان

  • Zoë R. Moutrie
  • Craig M. Lancaster
  • Litang Yu
چکیده

The purpose of this study was to investigate the impact of a dose control system (DCS) servo installed on two fully commissioned TomoTherapy Hi·Art II treatment units. This servo is designed to actively adjust machine parameters to control the output variation of a tomotherapy unit to within ± 0.5% of the nominal dose rate. Machine output, dose rate, and patient-specific quality assurance data were retrospectively analyzed for periods prior to and following the installation of the servo system. Quality assurance tests indicate a reduction in the rotational variation of the output during a procedure, where the peak-to-peak amplitude of the variation was ± 1.30 prior to DCS and equal to ± 0.4 with DCS. Comparing two tomotherapy unit static outputs over four years the percentage error was 1.05% ± 0.7% and -0.4% ± 0.66% and, once DCS was installed, was reduced to -0.22% ± 0.29% and -0.08% ± 0.16%. The results of the quality assurance tests indicate that the dose control system reduced the output variation of each machine for both static and rotational delivery, leading to an improvement in the overall performance of the machine and providing greater certainty in treatment delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical evaluation of TomoTherapy automatic roll correction

The TomoTherapy Hi·Art System allows the application of rotational corrections as a part of the pretreatment image guidance process. This study outlines a custom method to perform an end-to-end evaluation of the TomoTherapy Hi·Art roll correction feature. A roll-sensitive plan was designed and delivered to a cylindrical solid water phantom to test the accuracy of roll corrections, as well as th...

متن کامل

Stability of the Helical TomoTherapy Hi·Art II detector for treatment beam irradiations

The Hi·Art II Helical TomoTherapy (HT) unit is equipped with a built-in onboard MVCT detector used for patient imaging and beam monitoring. Our aim was to study the detector stability for treatment beam measurements. We studied the MVCT detector response with the 6 MV photon beam over time, throughout short-term (during an irradiation) and long-term (two times 50 days) periods. Our results show...

متن کامل

A planning study for palliative spine treatment using StatRT and megavoltage CT simulation†

Megavoltage CT (MVCT) simulation on the TomoTherapy Hi·Art system is an alternative to conventional CT for treatment planning in the presence of severe metal artifact. StatRT is a new feature that was implemented on the TomoTherapy operator station for performing online MVCT scanning, treatment planning and treatment delivery in one session. The clinical feasibility of using the StatRT techniqu...

متن کامل

Single‐fraction spine SBRT end‐to‐end testing on TomoTherapy, Vero, TrueBeam, and CyberKnife treatment platforms using a novel anthropomorphic phantom

Spine SBRT involves the delivery of very high doses of radiation to targets adjacent to the spinal cord and is most commonly delivered in a single fraction. Highly conformal planning and accurate delivery of such plans is imperative for successful treatment without catastrophic adverse effects. End-to-end testing is an important practice for evaluating the entire treatment process from simulati...

متن کامل

Prostate Helical Tomotherapy: A semi-empirical estimation of the scaling factor based on 2D approximating field

Background: In Helical Tomotherapy (HT), the scaling factor (SF) is the time in seconds that each leaf viewing a target would need to be open to deliver the prescribed dose. The SF is patient-specific and is used to calculate the rotational period of the gantry, and the total treatment time (TTT) of the HT. The SF is generally difficult to estimate. Currently, it takes about one hour t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015