Preanalytical factors that influence the Abbott TDx Fetal Lung Maturity II assay.

نویسندگان

  • David G Grenache
  • Curtis A Parvin
  • Ann M Gronowski
چکیده

BACKGROUND The TDx Fetal Lung Maturity II (FLM II) assay uses amniotic fluid to assess lung maturity of the unborn infant. We investigated common preanalytical factors that influence FLM results, including centrifugation, sample storage, and contamination by whole blood. METHODS We tested 18 specimens after centrifugation and after resuspension by vortex-mixing. We also analyzed 23 specimens stored at -20 degrees C for up to 448 days and then thawed (duplicate measurements), 20 specimens stored at 4 degrees C, and 24 specimens stored at room temperature. In addition, we evaluated the effects of whole blood diluted into 19 different specimens. RESULTS Centrifugation significantly decreased FLM II results from baseline (P <0.0001), and resuspension returned results to baseline values (P = 0.286). Storage at -20 degrees C produced highly variable results that demonstrated a nonsignificant negative trend associated with storage time. Specimens were stable for 24 h when stored at 4 degrees C and 16 h at room temperature. Blood contamination produced significantly positive differences in results only in specimens with baseline values < or =39 mg/g with a 5.8 mg/g increase in FLM II for every 0.1 x 10(12)/L increase in the erythrocyte count (slope = 58.4). CONCLUSIONS Resuspension of centrifuged specimens produces clinically valid FLM II results. Results from specimens stored at -20 degrees C can be highly variable and decrease over time. Results from specimens stored at 4 degrees C and at room temperature are stable for 24 and 16 h, respectively. Blood contamination up to 0.03 x 10(12) erythrocytes/L is acceptable for FLM II analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of lamellar body counts using three hematology analyzers.

The lamellar body count (LBC) represents an alternative method to the TDx-FLM II (Abbott Laboratories, Abbott Park, IL), which is planned to be discontinued, for assessing fetal lung maturity. Our objective was to validate the LBC on 3 hematology analyzers (Coulter LH 750 and Coulter Ac.T diff2, Beckman Coulter, Brea, CA; and Sysmex XE-2100, Sysmex, Mundelein, IL) to serve as a template for oth...

متن کامل

Assessment of the diagnostic accuracy of the TDx-FLM II to predict fetal lung maturity.

BACKGROUND Because respiratory distress syndrome (RDS) affects 1% of live births, accurate and rapid assessment of markers of fetal lung maturity is critical to clinicians in deciding whether to deliver a preterm infant. Our objective was to determine the optimal diagnostic cutoff value for the TDx-FLM II assay (Abbott Laboratories) for predicting clinically significant RDS. METHODS Amniotic ...

متن کامل

Multicenter evaluation of TDx test for assessing fetal lung maturity.

"TDx Fetal Lung Maturity," an automated assay that measures the relative concentrations of surfactant and albumin in amniotic fluid, was compared with the lecithin/sphingomyelin (L/S) ratio and phosphatidylglycerol determination at five clinical sites. A total of 695 amniotic fluid samples were analyzed, of which 312 were followed by delivery of the infant within three days of sample collection...

متن کامل

Measuring alveolar lavage fluid surfactant by fluorescence polarization.

We describe a procedure by which surfactant/albumin ratios in bronchoalveolar fluid (BALF) may be quantified with the Abbott Laboratories TDx fluorescence polarization analyzer and fetal lung maturity reagents. Adding albumin to BALF samples shifted the surfactant/albumin ratios to within the analytical range of the method. The analytical CV for assay of modified BALF samples was 2.9%. Ratios o...

متن کامل

Improved fluorescence polarization assay for use in evaluating fetal lung maturity. I. Development of the assay procedure.

We describe a fluorescence polarization assay for use in predicting fetal lung maturity, which is suitable for the TDx Analyzer (an automated fluorescence polarimeter). The assay requires 0.5 mL of amniotic fluid and approximately 30 min, and involves the fluorophore 1-palmitoyl-2(6-[(7-nitro-2, 1, 3-benzoxadiazol-4-yl)amino]caproyl) phosphatidylcholine. Reproducible polarization measurements d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 49 6 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2003