Ultrasonic device for measuring periodontal attachment levels

نویسندگان

  • J. E. Lynch
  • M. K. Hinders
چکیده

Periodontal disease is manifested clinically by a degradation of the ligament that attaches the tooth to the bone. The most widely used diagnostic tool for assessment of periodontal diseases, measurement of periodontal attachment loss with a manual probe, may overestimate attachment loss by as much as 2 mm in untreated sites, while underestimating attachment loss by an even greater margin following treatment. Manual probing is also invasive, which causes patient discomfort. This work describes the development and testing of an ultrasonographic periodontal probe designed to replace manual probing. It uses a thin stream of water to project an ultrasonic beam into the periodontal pocket, and then measures echoes off features within the pocket. To do so, the ultrasonic beam must be narrowed from 2 ~the diameter of the transducer! to 0.5 mm ~the approximate width of the periodontal pocket at the gingival margin!. The proper choice of transducer frequency, the proper method for controlling water flow from the probe, and a model for interpreting these echoes are also addressed. Initial results indicate that the device measures echoes from the hard tissue of the tooth surface, and that the periodontal attachment level can be inferred from these echoes. © 2002 American Institute of Physics. @DOI: 10.1063/1.1484235#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Efficacy of Full-Mouth Ultrasonic Debridement against Partial-Mouth Ultrasonic Debridement in the Treatment of Chronic Periodontitis: Full-Vs Partial-Mouth Debridement

Aim: To compare the clinical benefit of full-mouth ultrasonic debridement against partial-mouth ultrasonic debridement in patients with chronic periodontitis up to 3 months after therapy. Materials & Methods: Sixty patients with probing pocket depth ≥ 5 mm were randomly assigned to evaluate the clinical efficacy of full-mouth ultrasonic debridement against partial-mouth ultrasonic debridement i...

متن کامل

Simulations of Ultrasonographic Periodontal Probe Using the Finite Inte- gration Technique

Periodontal disease is one of the most pervasive dental diseases in older adults. It involves the loss of connective tissue attachment with subsequent destruction of tooth-supporting bone, leading to loss of teeth. Periodontal pocket depth is currently measured with an invasive manual probe, but adapting diagnostic ultrasound to this purpose can avoid the pain and inaccuracy inherent in manual ...

متن کامل

Patients' perception of pain during ultrasonic debridement: a comparison between piezoelectric and magnetostrictive scalers.

PURPOSE To compare patients' perception of discomfort, vibration and noise levels between piezoelectric and the magnetostrictive ultrasonic units during periodontal debridement. METHODS Periodontal debridement was performed on 75 subjects using a split-mouth design. Two quadrants on the same side were instrumented with a piezoelectric ultrasonic device (EMS Swiss Mini Master® Piezon) and the ...

متن کامل

Clinical evaluation of a protocol of subgingival debridement with Er:YAG laser in comparison to ultrasonic debridement: a randomized clinical trial

Objective:The aim of this parallel controlled randomized clinical trial was to evaluate the clinical efficacy of ultrasonic subgingival debridement in combination with Er:YAG laser as compared to full mouth ultrasonic subgingival debridement alone, after one year, in patients with initial to moderate chronic periodontitis. Material & Methods: 40 patients diagnosed with mild to moderate periodon...

متن کامل

Developing and Validating a New Wireless Wearable Device for Balance Measurement in Sport and Clinical Setting

One of the new clinical techniques to assess the lower body parameters is the wearable ultrasonic sensors. The device which can measure the static and dynamic balance abilities in sport and clinical setting by the traveled signals of ultrasonic transmitter and receiver between two feet was developed and validated. The new device consisted of a pressure gauge and a digital centimeter indicator a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002