CityFlux perfluorocarbon tracer experiments

نویسندگان

  • F. K. Petersson
  • D. Martin
  • I. R. White
  • S. J. Henshaw
  • D. E. Shallcross
چکیده

In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m. The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site. Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail. The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this. Correspondence to: D. E. Shallcross ([email protected]) The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urban Pollutant Transport and Infiltration into Buildings Using Perfluorocarbon Tracers

People spend the majority of their time indoors and therefore the quality of indoor air is worthy of investigation; indoor air quality is affected by indoor sources of pollutants and from pollutants entering buildings from outdoors. In this study, unique perfluorocarbon tracers were released in five experiments at a 100 m and ~2 km distance from a large university building in Manchester, UK and...

متن کامل

An airborne perfluorocarbon tracer system and its first application for a Lagrangian experiment

A perfluorocarbon tracer system (PERTRAS), specifically designed for Lagrangian aircraft experiments, has been developed by the Deutsches Zentrum für Luftund Raumfahrt (German Aerospace Center, DLR). It consists of three main parts: a tracer release unit (RU), an adsorption tube sampler (ATS), and a tracer analytical system. The RU was designed for airborne tracer release experiments; meanwhile...

متن کامل

Modified Perfluorocarbon Tracer Method for Measuring Effective Multizone Air Exchange Rates

A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents' level of exposure, by placing the dosers of tracer gas at locations that resemble indoor emission sources. To measure the 24-h-average effective air exchange rates in future surveys based on this proced...

متن کامل

Blood substitutes Artificial oxygen carriers: perfluorocarbon emulsions

Perfluorocarbon emulsions are being clinically evaluated as artificial oxygen carriers to reduce allogeneic blood transfusions or to improve tissue oxygenation. Perfluorocarbon emulsions are efficacious in animal experiments, and in humans they are well tolerated and at least as successful to reverse physiologic transfusion triggers than autologous blood. Perfluorocarbon emulsions may be used i...

متن کامل

Partial liquid ventilation: effects of liquid volume and ventilatory settings on perfluorocarbon evaporation.

During partial liquid ventilation perfluorocarbons are eliminated mainly by evaporation via the airways. The effects of intrapulmonary perfluorocarbon volume, respiratory rate, tidal volume, as well as the level of end-expiratory pressure on perfluorocarbon elimination from isolated lungs, were studied. Nonperfused rabbit lungs underwent partial liquid ventilation (2-15 mL x kg(-1) perfluorocar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010