Background. Lung transplantation is the optimal treatment for end stage lung disease. Donor shortage necessitates single-lung transplants (SLT), yet minimal data exists regarding regional ventilation in diseased versus transplanted lung measured by Electrical Impedance Tomography (EIT). Method. We aimed to determine regional ventilation in six SLT outpatients using EIT. We assessed end expiratory volume and tidal volumes. End expiratory lung impedance (EELI) and Global Tidal Variation of Impedance were assessed in supine, right lateral, left lateral, sitting, and standing positions in transplanted and diseased lungs. A mixed model with random intercept per subject was used for statistical analysis. Results. EELI was significantly altered between diseased and transplanted lungs whilst lying on right and left side. One patient demonstrated pendelluft between lungs and was therefore excluded for further comparison of tidal variation. Tidal variation was significantly higher in the transplanted lung for the remaining five patients in all positions, except when lying on the right side. Conclusion. Ventilation to transplanted lung is better than diseased lung, especially in lateral positions. Positioning in patients with active unilateral lung pathologies will be implicated. This is the first study demonstrating changes in regional ventilation, associated with changes of position between transplanted and diseased lung.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Literature List Electrical Impedance Tomography

Electrical impedance tomography (EIT) is a non-invasive, radiation-free tool to monitor regional changes in ventilation. This report describes, for the first time, that unilateral atelectasis in an extremely low birth weight infant results in a loss of regional ventilation measured by EIT in the affected lung. Conclusion: EIT is currently the most promising technique to monitor regional lung ae...

متن کامل

Regional ventilation distribution in the first 6 months of life.

Electrical impedance tomography (EIT) has been used to study regional ventilation distribution in neonatal and paediatric lung disease; however, little information has been obtained in healthy newborns and infants. Data on regional ventilation distribution and regional filling characteristics were obtained using EIT in the neonatal period, at 3 and 6 months of age, in spontaneously breathing in...

متن کامل

Regional Ventilation Distribution in the First Six Months of Life

Electrical Impedance Tomography has been used to study regional ventilation distribution in neonatal and paediatric lung disease. Little information has been obtained in healthy newborns and infants. Data on regional ventilation distribution and regional filling characteristics has been obtained with EIT in the neonatal period, at 3 and 6 months of age in spontaneously breathing infants during ...

متن کامل

Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial

INTRODUCTION Computed tomography of the lung has shown that ventilation shifts from dependent to nondependent lung regions. In this study, we investigated whether, at the bedside, electrical impedance tomography (EIT) at the cranial and caudal thoracic levels can be used to visualize changes in ventilation distribution during a decremental positive end-expiratory pressure (PEEP) trial and the r...

متن کامل

Assessment of regional ventilation in acute respiratory distress syndrome by electrical impedance tomography.

Mechanical ventilation in acute respiratory distress syndrome (ARDS) incurs a risk of ventilator-associated lung injury (VALI) from inhomogeneous conditions and different properties of dependent and non-dependent lung regions at risk of atelectasis and overdistension, respectively. Electrical impedance tomography (EIT) offers regional ventilation assessment to optimise treatment with mechanical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016