Estimating the critical duration for temporal summation of standard achromatic perimetric stimuli.

نویسندگان

  • Pádraig J Mulholland
  • Tony Redmond
  • David F Garway-Heath
  • Margarita B Zlatkova
  • Roger S Anderson
چکیده

PURPOSE To estimate the critical duration of temporal summation for achromatic Goldmann III stimuli under the conditions of standard automated perimetry (SAP) and quantify response variability for short-duration stimuli. METHODS Contrast thresholds were gathered using the method of constant stimuli for seven circular (0.48° diameter) incremental stimuli of varying duration (sum-of-frames equivalent: 8.3-198.3 ms), at an eccentricity of 8.8° along the four principal meridians of the visual field in two healthy, psychophysically experienced observers. Stimuli were presented on a high-resolution cathode ray tube display with a background luminance of 10 cd/m(2). Psychometric functions were fitted using a probit model and nonparametric local-linear analysis. The critical duration was estimated using iterative two-phase regression analysis, the results also being compared with values produced using previously published methods of analysis. RESULTS The median critical duration estimated using iterative two-phase regression analysis was 27.7 ms (IQR 22.5-29.8). A slight steepening of the psychometric function slope (lower variability) was observed for longer stimulus durations, using both probit and local-linear analysis techniques, but this was not statistically significant. CONCLUSIONS Critical duration estimates in this study are substantially shorter than those previously reported for a Goldmann III stimulus, under the conditions of SAP. Further work is required to firmly establish the relationship between measurement variability and the degree of local temporal and spatial summation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Age on the Temporal Summation of Achromatic Perimetric Stimuli.

PURPOSE To examine the temporal summation of a Goldmann III-sized stimulus under the conditions of standard automated perimetry in healthy participants of varying age. METHODS Twenty-seven healthy individuals of varying age (24-80 years) were tested. Achromatic contrast thresholds were measured for seven 0.48° diameter (near Goldmann III) spot stimuli of varying presentation duration (1-24 fr...

متن کامل

Spatiotemporal Summation of Perimetric Stimuli in Early Glaucoma.

PURPOSE To investigate achromatic temporal summation under the conditions of standard automated perimetry (SAP), using a Goldmann III (GIII) stimulus and a stimulus scaled to the local area of complete spatial summation (Ricco's area) in open-angle glaucoma (OAG) patients and healthy age-similar control participants. METHODS Twenty patients with OAG (mean age, 63 years; mean MD, -3.3 dB) and ...

متن کامل

Effect of varying CRT refresh rate on the measurement of temporal summation.

PURPOSE To quantify the effect of cathode-tube-ray (CRT) monitor refresh rate on the measurement of the upper limit of complete temporal summation (critical duration) in the peripheral visual field of healthy observers. METHODS Contrast thresholds were measured for seven achromatic spot stimuli (diameter 0.48°) of varying duration (nominal values: 10-200 ms) at an eccentricity of 8.8° along t...

متن کامل

Sensitivity loss in early glaucoma can be mapped to an enlargement of the area of complete spatial summation.

PURPOSE The area of complete spatial summation (Ricco's area) is the largest stimulus size for which area × intensity is constant at threshold. The authors sought to investigate whether Ricco's area changes in early glaucoma to account for the decreased visual signal/noise ratio that may accompany retinal ganglion cell loss. METHODS Spatial summation functions were measured, and Ricco's area ...

متن کامل

Colour–luminance interactions in binocular summation

Using a noise-masking paradigm we test the notion of binocular detection mechanisms that combine luminance and colour contrast. Binocular summation was measured for achromatic and red-green isoluminant Gabor stimuli over a range of temporal frequencies and was compared with and without the presence of a two-dimensional, dynamic, luminance noise mask (correlated). While we found that luminance n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 1  شماره 

صفحات  -

تاریخ انتشار 2014