Performance of two portable meters and a benchtop analyzer for blood glucose concentration measurement in rabbits.

نویسندگان

  • Paolo Selleri
  • Nicola Di Girolamo
  • Gianluca Novari
چکیده

OBJECTIVE To evaluate performance of a human portable blood glucose meter (PBGM), a veterinary PBGM, and a veterinary benchtop analyzer for measuring blood glucose concentration in rabbits and to evaluate the effect of sample characteristics on their performance. DESIGN Observational prospective cross-sectional study. SAMPLE Blood samples from 89 pet rabbits. PROCEDURES Blood glucose concentration was measured with a human PBGM (n = 89 rabbits), a veterinary PBGM (89), and a benchtop analyzer (32) and compared with results obtained with plasma in a laboratory analyzer (hexokinase method). RESULTS The human PBGM underestimated blood glucose concentration, had decreased accuracy at high Hcts, and had the lowest total error observed (11.4%). The veterinary PBGM overestimated blood glucose concentration, had decreased accuracy at low Hcts and at high blood glucose concentrations, and had the highest total error (15.5% and 29.8% for canine and feline settings, respectively). The benchtop analyzer had good accuracy and was not influenced by Hct or glucose concentrations. Clinical errors would have occurred in 0% of cases with the human PBGM and with the benchtop analyzer and in 9% (canine setting) to 6.7% (feline setting) of cases with the veterinary PBGM. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that use of the human PBGM evaluated in this study would be acceptable for point-of-care testing of blood glucose concentration in rabbits when benchtop analyzers are not available. The use of the veterinary PBGM evaluated in this study may alter both treatment and diagnostic decisions because of the overestimation of glucose concentrations in some rabbits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

OBJECTIVE To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). ANIMALS 20 healthy adult Hispaniolan Amazon parrots. PROCEDURES A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) fro...

متن کامل

ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine.

Portable blood glucose meters (PBGM, glucometers) are a convenient, cost effective, and quick means to assess patient blood glucose concentration. The number of commercially available PBGM is constantly increasing, making it challenging to determine whether certain glucometers may have benefits over others for veterinary testing. The challenge in selection of an appropriate glucometer from a qu...

متن کامل

Interrelationship of βeta-2 microglobulin, blood urea nitrogen and creatinine in streptozotocin -induced diabetes mellitus in rabbits

Measurement of serum creatinine (Cr) and blood urea nitrogen (BUN) are used as indicators of glomerular filtration rate. The increased levels of these biomarkers are usually detectable at advanced stages of kidney complications. The aim of this study was to find the interrelationship of beta-2 microglobulin (β2M), BUN and Cr in streptozotocin (STZ)-induced diabetes mellitus in rabbits. Diabetes...

متن کامل

Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

BACKGROUND Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Veterinary Medical Association

دوره 245 1  شماره 

صفحات  -

تاریخ انتشار 2014