Total protein determination in urine: elimination of a differential response between the coomassie blue and pyrogallol red protein dye-binding assays.
نویسندگان
چکیده
BACKGROUND The total protein content of urine is a good index of renal function, but its determination is unreliable. Protein dye-binding assays are simple, but they characteristically lack a uniform response to different proteins. METHODS We investigated a differential response of the Sigma Microprotein Coomassie Brilliant Blue (CBB) and Pyrogallol Red-molybdate (PRM) protein dye-binding assays to urine, using human albumin, albumin/globulin, or urinary protein as calibrator. RESULTS The urine protein values (n = 60) obtained with the CBB assay were 110-13 500 mg/L (mean, 2390 mg/L) compared with 160-18 300 mg/L (mean, 3470 mg/L) obtained with the PRM assay (CBB:PRM protein concentration ratio, 0.46-0.88, mean, 0. 69 +/- 0.10). The differential response was highly reproducible as indicated by Sigma urine control Level 1 (within-day CBB:PRM ratio, 0.68 +/- 0.02; between-day CBB:PRM ratio, 0.67 +/- 0.04) and Sigma urine control Level 2 (within-day CBB:PRM ratio, 0.60 +/- 0.01; between-day CBB:PRM ratio, 0.59 +/- 0.02). The use of urinary protein as a calibrator (rather than human albumin) greatly improved the agreement between the assays when applied to urine (y(CBB) = 0. 972x(PRM) - 16 vs y(CBB) = 0.685x(PRM) + 17). In studies using urine controls, this calibrator also improved agreement between the CBB, PRM, trichloroacetic acid (TCA), and benzethonium chloride protein methods and, to a lesser extent, agreement with the TCA-Ponceau S method. CONCLUSION The use of a urinary protein calibrator improves the agreement between different methods used to determine total protein in urine.
منابع مشابه
Rapid detection of cystic fibrosis transmembrane conductance regulator gene IVS8 5T variant by real-time PCR.
with specific marker proteins in routine laboratories , in which nephelometric instrumentation is frequently available but manpower is limited and the expert knowledge required to interpret proteinuria is lacking. improved pyrogallol red-molybdate method for determining total urinary protein. Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 auto...
متن کاملComparing Invasive and Non-Invasive of Isolated Shigella flexneri by Electron Microscopy of Cell Culture, SDS-PAGE and Congo Red Method
The aim of this study was to compare invasive and non-invasive strains of Shigella flexneri isolated from Tehran by a 120 kDa protein band by SDS-PAGE, electron microscopy of cell culture and Congo red dye methods. Methods: S. flexneri strains were isolated by standard bacterial methods from fecal specimens of children attending to the 3 children’s hospitals. Phenotype analysis for screening v...
متن کاملCreatinineClearance:Enzymaticvs Jaff#{233} Determinationsof Creatininein Plasmaand Urine
staff Coomassie Brilliant Blau G250. J Clin Chem Cm Biochem 1981;19:203-8. 5. Peterson GL Determination of total protein.Methods Enzymol 1983;91:95-119. 6. SedmakJJ,GroesbergSE.A rapid, sensitive, and versatile assay for protein using Coomassie Brilliant Blue G250. Anal Biochem 1977;79:544-52. 7. JohnsonA, Lott JA. Standardization of the Coomassie Blue method forcerebrospinal fluid proteins. Cl...
متن کاملProblems with the estimation of urine protein by automated assays.
OBJECTIVES Most clinical laboratories replaced their manual precipitation techniques for the determination of urinary protein with automated dye binding assays or benzethonium chloride-turbidimetric assays. Few studies have validated these assays for the measurement of urinary proteins in the normal range. DESIGN AND METHODS This study compares four automated assays for the measurement of uri...
متن کاملTable 1. CBB-Measured Protein Concentrations (gIL) In Urine SpecImens Diluted to Achieve Bluret-Predicted ProteIn Concentrations
Urine SpecImens Diluted to Achieve Bluret-Predicted ProteIn Concentrations of 4 to 0.2 gIL The Coomassie Brilliant Blue (CBB) dye-binding method for determining total protein in urine is widely used in clinical laboratories because it is sensitive, easily automated, and free from interference by many clinically relevant substances (1-6). However, it yields different results for the same concent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 46 3 شماره
صفحات -
تاریخ انتشار 2000