Scattering effects of irradiation on surroundings calculated for a small dental implant.

نویسندگان

  • Reinhard E Friedrich
  • Manuel Todorovic
  • Max Heiland
  • Hanna A Scheuer
  • Andreas Krüll
چکیده

A fundamental improvement of restorative dentistry is the compensation of missing teeth by insertion of artificial dental roots allowing retention of dental prosthesis. The function of dental implants conserves a permanent perforation of the mucosa and upholds a non-physiological contact of bone with foreign material and oral micro-organisms. Occasionally head and neck cancer patients are scheduled to receive radiotherapy but are wearing dental implants. An earlier study had shown that the distribution of x-rays is noteworthily changed when dental implants are present in the irradiation field. New implants of smaller size are currently being designed that allow sufficient retention for dental prosthesis. The aim of this consecutive study was to calculate alterations in the irradiated bone caused by a foreign body, representing an implant of reduced size and physical qualities equivalent to titanium, using a stochastic (Monte Carlo) simulation. A clinical linear accelerator was simulated using BEAM/EGS4. The calculations showed that the presence of a dimension-reduced implant results in remarkable differences of the dose distribution all around the implant. Titanium dental implants of reduced size located in the field of irradiation were capable of causing significant radiation scattering. Similar to standard implants, the risk for dose enhancement was notably important for the bone in direct contact with the implant. All therapists involved in the therapy of cancer patients undergoing head and neck radiotherapy should consider the impact of dental implants on the radiation beam as a catalyst of osteoradionecrosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of scattering effects of irradiation on surroundings using the example of titanium dental implants: a Monte Carlo approach.

Occasionally, head and neck cancer patients treated with high-energy X-rays and gamma rays have titanium dental implants. The aim of this study was to calculate alterations in the irradiated bone caused by a foreign body, representing a titanium implant in size and physical qualities, using a stochastic (Monte Carlo) simulation. A clinical linear accelerator was simulated using BEAM/EGS4. The c...

متن کامل

Small field size dose-profile measurements: A comparison between Eclipse™ treatment planning system with NIPAM polymer gel dosimeter dose measurement

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

متن کامل

تحلیل پایداری ایمپلنت دندانی و بررسی تاثیر عوامل موثر بر اتصال ایمپلنت- استخوان به کمک مدل اصطکاکی تماس

Background and Aims: Relative displacement of the implant with respect to bone and quality of bone-implant contact play critical roles in the dental implant stability. The goal of this study was to investigate the dental implant stability using non-linear finite elements method. Therefore, bone-implant relative displacement due to applied force to the implant was calculated, and then an appropr...

متن کامل

The accuracy of various torque wrenches used in dental implant systems

Introduction: The purpose of this study was to compare the accuracy of the torque wrenches used in different dental implant systems. Methods: We evaluated 42 torque wrenches used in different dental clinics in Mashhad, Iran, using a digital torque meter (Mark 10). High (25, 30 and 35 N·cm) and low (15 N·cm) levels of torque were examined. Ten tests were performed on each wrench, and the mean va...

متن کامل

Dimensional changes of three-unit implant-supported zirconia frameworks from scanning to sintering

Background and Aims: Passive fitness of implant frameworks are important factors for long-term success of dental implant restorations. The aim of this in vitro study was to evaluate the dimensional changes of implant supported zirconia frameworks fabricated by Zirkonzahn CAD/CAM system during fabrication stages. Materials and Methods: The master model of 3-unit FDP was made of two implant abut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anticancer research

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 2012