Bioglass implant-coating interactions in synthetic physiological fluids with varying degrees of biomimicry

نویسندگان

  • AC Popa
  • GE Stan
  • MA Husanu
  • I Mercioniu
  • LF Santos
  • HR Fernandes
  • JMF Ferreira
چکیده

Synthetic physiological fluids are currently used as a first in vitro bioactivity assessment for bone grafts. Our understanding about the interactions taking place at the fluid-implant interface has evolved remarkably during the last decade, and does not comply with the traditional International Organization for Standardization/final draft International Standard 23317 protocol in purely inorganic simulated body fluid. The advances in our knowledge point to the need of a true paradigm shift toward testing physiological fluids with enhanced biomimicry and a better understanding of the materials' structure-dissolution behavior. This will contribute to "upgrade" our vision of entire cascades of events taking place at the implant surfaces upon immersion in the testing media or after implantation. Starting from an osteoinductive bioglass composition with the ability to alleviate the oxidative stress, thin bioglass films with different degrees of polymerization were deposited onto titanium substrates. Their biomineralization activity in simulated body fluid and in a series of new inorganic-organic media with increasing biomimicry that more closely simulated the human intercellular environment was compared. A comprehensive range of advanced characterization tools (scanning electron microscopy; grazing-incidence X-ray diffraction; Fourier-transform infrared, micro-Raman, energy-dispersive, X-ray photoelectron, and surface-enhanced laser desorption/ionization time-of-flight mass spectroscopies; and cytocompatibility assays using mesenchymal stem cells) were used. The information gathered is very useful to biologists, biophysicists, clinicians, and material scientists with special interest in teaching and research. By combining all the analyses, we propose herein a step forward toward establishing an improved unified protocol for testing the bioactivity of implant materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نقش پوشش های بیوسرامیکی در موفقیت ایمپلنت ها

Characterization of bioceramics coating and evaluation of the influence of kind of coating on the implantation has been developed in recent years.Different bioceramics coating like calcium phosphate, hydroxyapatite, fluorapatite and bioglass were coated on dental and orthopedic implants. In-vitro and in-vivo experiments were done for evolution of implant success and reliability and study of fac...

متن کامل

Ion-Doped Silicate Bioceramic Coating of Ti-Based Implant

Titanium and its alloy are known as important load-bearing biomaterials. The major drawbacks of these metals are fibrous formation and low corrosion rate after implantation. The surface modification of biomedical implants through various methods such as plasma spray improves their osseointegration and clinical lifetime. Different materials have been already used as coatings on biomedical implan...

متن کامل

بررسی تأثیر روش‌های پوشش‌دهی مختلف بر استحکام باند رزین به زیرکونیا

Objective: A clinical challenge of using zirconia frameworks is to achieve adequate bond with different substrates. This study aimed to evaluate the effect of bioglass and silica coating of zirconia substrates on microshear bond strength of resin cement to tetragonal zirconia. Methods: This laboratory experimental study was conducted on zirconia discs. A total of 120 YTZP zirconia (Zirkonzahn) ...

متن کامل

FTIR Analysis of Apatite Formation on Bioactive Glass Coatings on Ti Alloys

The objective of our work is to improve the osseointegration of titanium (and its alloys) used in dental and orthopedic applications. To do this, we have been coating these metals with glasses whose compositions are based upon Bioglass®, which is a bioactive glass developed by Hench et al. Bioactive glasses have the property of forming an apatite layer (and therefore can chemically bond to bone...

متن کامل

Mechanical properties of electrophoretically deposited 45S5 bioglass-graphene oxide composite coatings

Bioglass-graphene oxide composites can be served as a high-potential candidate for biomedical applications due to its specific mechanical properties. In this study, the 45S5 bioactive glass (BG) - graphene oxide (GO) composite containing 2 wt. % GO was coated on titanium alloy via electrophoretic deposition process (EPD). The synthesized GO was incorporated into BG coating to improve the mechan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017