Experimental studies of thermal environment and contaminant transport in a commercial aircraft cabin with gaspers on.
نویسندگان
چکیده
Gaspers installed in commercial airliner cabins are used to improve passengers' thermal comfort. To understand the impact of gasper airflow on the air quality in a cabin, this investigation measured the distributions of air velocity, air temperature, and gaseous contaminant concentration in five rows of the economy-class section of an MD-82 commercial aircraft. The gaseous contaminant was simulated using SF6 as a tracer gas with the source located at the mouth of a seated manikin close to the aisle. Two-fifths of the gaspers next to the aisle were turned on in the cabin, and each of them supplied air at a flow rate of 0.66 l/s. The airflow rate in the economy-class cabin was controlled at 10 l/s per passenger. Data obtained in a previous study of the cabin with all gaspers turned off were used for comparison. The results show that the jets from the gaspers had a substantial impact on the air velocity and contaminant transport in the cabin. The air velocity in the cabin was higher, and the air temperature slightly more uniform, when the gaspers were on than when they were off, but turning on the gaspers may not have improved the air quality.
منابع مشابه
Design and Experimental Analysis of Aircraft Air Distribution Systema
In this paper, the methodology of aircraft air distribution system has been analyzed theoretically and experimentally. To achieve that, ducting pressure loss and air flow throw gaspers calculations has been done for cabin ducts in according to exact location of individual air distribution system in the cabin. The length of gasper air flow was compared with the distance between gasper outlet and...
متن کاملInfluence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft.
Potential causalities due to airborne disease transmission and risk of chem-bio terrorism in commercial airliner cabins can be reduced by fast responses. Fast responses are only possible by using sensors at appropriate locations in the cabins. Cost, size and weight factors restrict the number of sensors that could be installed inside a cabin. Since release locations and seating patterns of pass...
متن کاملExperimental and Numerical Investigation of Airflow and Contaminant Transport in an Airliner Cabin Mockup
The study of airflow and contaminant transport in airliner cabins is very important for creating a comfortable and healthy environment. This paper shows the results of such a study by conducting experimental measurements and numerical simulations of airflow and contaminant transport in a section of half occupied, twin-aisle cabin mockup. The air velocity and air temperature were measured by ult...
متن کاملNovel air distribution systems for commercial aircraft cabins
Air distribution systems in commercial aircraft cabins are important for providing a healthy and comfortable environment for passengers and crew. The mixing air distribution systems used in existing aircraft cabins create a uniform air temperature distribution and dilute contaminants in the cabins. The mixing air distribution systems could spread infectious airborne diseases. To improve the air...
متن کاملMeasurements of Indoor Air Quality on Commercial Transport Aircraft
Exposures to cabin environmental contaminants were measured on 36 commercial transport aircraft. The objectives were to characterize levels of contaminants and evaluate the relationship between flight factors such as aircraft size, occupancy, ventilation, and flight length, and environmental parameters. Monitoring was conducted at two coach locations for the duration of the flight for VOCs, nit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indoor air
دوره 26 5 شماره
صفحات -