A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

نویسندگان

  • Xinqiang Yan
  • Rong Xue
  • Xiaoliang Zhang
چکیده

Proton and heteronuclear MRI/MRS using dual-tuned (DT) coils could provide both anatomical and metabolic images without repositioning the subject. However, it is technologically challenging to attain sufficiently electromagnetic (EM) decoupling between the heteronuclear channel and proton channel, and keep the imaging areas and profiles of two nuclear channels highly matched. In this study, a hybrid monopole/loop technique was proposed for DT coil design and this technique was validated by implementing and testing a DT (1)H/(23)Na coil for MR imaging at 7T. The RF fields of the monopole ((1)H channel) and regular L/C loop ((23)Na channel) were orthogonal and intrinsically EM decoupled. Bench measurement results demonstrated the isolation between the two nuclear channels was better than -28 dB at both nuclear frequencies. Compared with the conventional DT coil using trap circuits, the monopole/loop DT coil had higher MR sensitivity for sodium imaging. The experimental results indicated that the monopole/loop technique might be a simple and efficient design for multinuclear imaging at ultrahigh fields. Additionally, the proposed DT coils based on the monopole/loop technique can be used as building blocks in designing multichannel DT coil arrays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Development of New Dual Tuned Coil and Array for Multi Nuclear Imaging

Introduction: MR imaging of nuclei other than hydrogen has been used to investigate metabolism in humans and animals. However, MRI observable nuclei other than hydrogen are not as abundant and as a result the image SNR is low. Therefore, dual-tuned radio frequency (RF) coils are required for these studies, in which high-resolution structural images are acquired using hydrogen and metabolic info...

متن کامل

1H and 23Na MRI of Rat Head at 4 Tesla with a Simple Double-Tuned RF Surface Coil

Introduction MRI is proving to be a very useful tool for sodium (23Na) quantification in animal models of stroke, ischemia, and cancer. To obtain co-registered anatomical (1H) and physiological (23Na) information a dual-frequency RF coil is required, and several designs of surface RF coils were previously reported [1-7]. Aims We present the practical design of a dual-frequency RF surface coil t...

متن کامل

Reengineered Helmet Coil for Human Brain Studies at 3 Tesla

We describe the further development of a circularly polarized helmet coil for magnetic resonance imaging (MRI) of the human brain at 3 T. The coil is used in transmit and receive (transceive) mode, a useful alternative over commercially available quadrature headcoils with scanners where phased arrays are unavailable. The coil is simple to build. Its structure is based on an assembly of two copl...

متن کامل

RF instrumentation for same‐breath triple nuclear lung MR imaging of 1H and hyperpolarized 3He and 129Xe at 1.5T

PURPOSE The hyperpolarized gases (3)He and (129)Xe have distinct properties and provide unique and complementary functional information from the lungs. A triple-nuclear, same-breath imaging examination of the lungs with (1)H, (3)He, and (129)Xe can therefore provide exclusive functional information from the gas images. In addition, the (1)H images provide complementary co-registered structural ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Quantitative imaging in medicine and surgery

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2014