PURPOSE Direct addition of doses between plans with different fractionation fails to provide accurate dose-response information to anticipate clinical outcome. To combine different fractionation patterns, first-order biological model correction for dose-rate must be included. Moreover, 3-D isoeffect patterns of the combined doses must be displayed so that overlap area to elegant volumes can be avoided. The linear quadratic (LQ) model and biologically effective dose (BED) method were used to produce a combined plan in equivalent 2 Gy fractions (EQD2) for radiosurgery and conventional 3D radiotherapy. METHODS For patients with multiple courses of radiotherapy, dose distributions of the prior and boost treatment plans were converted to BED. The fraction size specified by the prescription was applied globally for each BED calculation, α/β ratio of 10 and 2.5 was used for early and late effect, respectively. Image registration with CT or MR was performed for initial and boost plans. The registration information was applied to dose distributions to obtain the composite EQD2. RESULTS As a demonstration of this method, two patients were selected who had combined treatments from substantially different modalities. A patient with liver cancer initially received radiotherapy of 30 Gy/10 Fx and re-irradiation with CyberKnife radiosurgery (15 Gy/1 Fx). The combined plan showed that the PTV received EQD2 of 63.8 Gy. Another patient had brain metastasis treated with GammaKnife of 18 Gy (50% isodose) followed by conventional 3D whole brain radiation of 30 Gy/10 Fx. The minimal combined tumor EQD2 was 74.5 Gy. Early and late calculated responses showed that all critical organ doses were within tolerance. CONCLUSIONS For patients receiving radiation with different fractionation schemes, combined isoeffective dose distributions were calculated and displayed. In both cases, crucial information regarding 3-D dose distributions assisted the physicians in determining whether tolerance limits of overlap areas of retreated critical structures were preserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Filling the gap in central shielding: three-dimensional analysis of the EQD2 dose in radiotherapy for cervical cancer with the central shielding technique

This study aimed to provide accurate dose distribution profiles of radiotherapy for cervical cancer when treated with the central shielding technique by analysing the composite 3D EQD2 dose distribution of external beam radiotherapy (EBRT) plus intracavitary brachytherapy (ICBT). On a phantom, four patterns of the combinations of whole pelvis irradiation (WP) (4 fields), pelvis irradiation with...

متن کامل

The comparison of dose distribution of different 3D conformal and conventional radiotherapy plans for gastric cancer

Aims: It was aimed to investigate postoperative conformal radiotherapy planning that provides the best target volume and the least dose for critical organs in cancers of stomach. Methods: This study was conducted on the CT simulation images of thirty patients diagnosed with gastric cancer. Target volumes and the organs at risk were contoured. AP-PA reciprocal parallel field conventional plan an...

متن کامل

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...

متن کامل

Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012