Development, Test and Validation of a Mechatronic Device for Spasticity Quantification
نویسندگان
چکیده
Spasticity is a common pathological phenomenon in clinical practices, frequently expressed as a stroke, multiple sclerosis or cerebral palsy. The accurate quantification of spasticity allows early action to prevent the potentially irreversible consequences. The aim of this work is to develop and implement a mechatronic device for the accurate quantification of spasticity, which is able to differentiate spasticity from other motor disorders. The proposed method is based on the quantification of the tonic stretch reflex threshold (TSRT) for the assessment of the range of motion of the limb affected by spasticity. In order to validate the developed device, experimental trials have been conducted, considering the flexor muscle of the elbow joint. The developed device was tested, first in a laboratory environment with healthy subjects and secondly, in a clinical environment with the collaboration of patients with spasticity. The evaluations in th clinical environment were performed on three different days in order to evaluate the reproducibility of the obtained results. The experimental trials confirm the sensibility, reproducibility and reliability of spasticity quantification based on the TSRT method. This project has been developed in cooperation with the Hospital of Braga and Fisimaia rehabilitation clinic, both in Portugal.
منابع مشابه
An approach for spasticity quantification based on the stretch reflex threshold
Spasticity is a common and complex motor disorder that affects more than 12 million persons in the world. There are several studies on spasticity quantification in the literature but there is still a need for measurement improvements. This paper presents the design of a mechatronic device for spasticity quantification, in joint of ankle, elbow and knees. This approach is based on the velocity d...
متن کاملDevelopment and Validation of Sound Transmission Loss Measurement System for Measuring Muffler Performance
Muffler is a part of the vehicle exhaust system that absorb or reflect sound waves to reduce exhaust noise. One of the most important determinants of a muffler performance is the amount of attenuation that has on its input wave; this parameter is known as sound transmission loss. Four - mic standard test is one way to determine this parameter which is used in this paper. In this study, a test d...
متن کاملThe effect of NDT and BTX-A injection on muscle spasticity
The aim of this study was to compare the effect of neuro-development treatment (NDT) technique and NDT plus botulinum toxin type A (BTX-A) injection on the reduction of spasticity and improvement of the quality of movement patterns of lower limb in hemiplegic patients. For this purpose, 15 hemiplegic (8 female and 7 male cases) with an age range of 27-70 years participated in this study. The pa...
متن کاملIntelligent Robotised Physiotherapy Tested on an 8-dof Mechatronic Arm
The successful rehabilitation of people with upper limb neuro-motor impairment depends largely on the appropriate selection and validation of a set of exercises. In this paper a knowledge-based system (KBS) for selecting a set of exercises to suit a particular patient status is proposed. Also a model of a mechatronic limb that simulates the human arm spastic characteristics will be developed. T...
متن کاملThe effect of NDT and BTX-A injection on muscle spasticity
The aim of this study was to compare the effect of neuro-development treatment (NDT) technique and NDT plus botulinum toxin type A (BTX-A) injection on the reduction of spasticity and improvement of the quality of movement patterns of lower limb in hemiplegic patients. For this purpose, 15 hemiplegic (8 female and 7 male cases) with an age range of 27-70 years participated in this study. The pa...
متن کامل