Noninvasive monitoring of Pirenoxine Sodium concentration in aqueous humor based on dual-wavelength iris imaging technique
نویسندگان
چکیده
We present a noninvasive method of detecting substance concentration in the aqueous humor based on dual-wavelength iris imaging technology. Two light sources, one centered within (392 nm) and the other centered outside (850 nm) of an absorption band of Pirenoxine Sodium, a common type of drugs in eye disease treatment, were used for dual-wavelength iris imaging measurement. After passing through the aqueous humor twice, the back-scattering light was detected by a charge-coupled device (CCD). The detected images were then used to calculate the concentration of Pirenoxine Sodium. In eye model experiment, a resolution of 0.6525 ppm was achieved. Meanwhile, at least 4 ppm can be distinguished in in vivo experiment. These results demonstrated that our method can measure Pirenoxine Sodium concentration in the aqueous humor and its potential ability to monitor other materials' concentration in the aqueous humor.
منابع مشابه
Dual-wavelength polarimetry for monitoring glucose in the presence of varying birefringence.
In a continuing effort to develop a noninvasive means of monitoring glucose levels using the aqueous humor of the eye, a dual-wavelength system is developed to show that varying birefringence, similar to what is seen with a moving cornea, can be compensated. In this work, a dual-wavelength, closed-loop system is designed and a model is developed to extract the glucose concentration information....
متن کاملNoninvasive monitoring of glucose concentration using differential absorption low-coherence interferometry based on rapid scanning optical delay line
A non-invasive method of detecting glucose concentration using differential absorption low-coherence interferometry (DALCI) based on rapid scanning optical delay line is presented. Two light sources, one centered within (1625 nm) a glucose absorption band, while the other outside (1310 nm) the glucose absorption band, are used in the experiment. The low-coherence interferometry (LCI) is employe...
متن کاملReal-time, closed-loop dual-wavelength optical polarimetry for glucose monitoring.
The development of a real-time, dual-wavelength optical polarimetric system to ultimately probe the aqueous humor glucose concentrations as a means of noninvasive diabetic glucose monitoring is the long-term goal of this research. The key impact of the work is the development of an approach for the reduction of the time-variant corneal birefringence due to motion artifact, which is still a limi...
متن کاملDynamic sodium chemical shift imaging for the study of aqueous humor flow.
Ocular images were obtained using sodium chemical shift imaging (CSI) and 1,4,7,10-tetraazacyclododecane-N,N'N",N"'-tetramethylenephospho nate thulium (III) [Tm(DOTP)5-], a paramagnetic chemical shift reagent. After injecting the shift reagent into the anterior chamber of rabbits, serial imaging was done, monitoring the change in chemical shift with time. Sodium CSI produced images of the eye i...
متن کاملThe inhibitory effect of pentobarbital Na on aqueous humor formation.
Numerous investigators* have utilized pentobarbital Na as an anesthetic in monkeys for experiments on aqueous humor dynamics. Eakins showed that pentobarbital Na probably decreased the rate of aqueous humor formation in the cat eye. To our knowledge, similar inhibitory responses, if any, on aqueous humor formation have never been studied in monkeys. This report was conducted to determine if pen...
متن کامل