MinION Analysis and Reference Consortium: Phase 2 data release and analysis of R9.0 chemistry
نویسندگان
چکیده
BACKGROUND Long-read sequencing is rapidly evolving and reshaping the suite of opportunities for genomic analysis. For the MinION in particular, as both the platform and chemistry develop, the user community requires reference data to set performance expectations and maximally exploit third-generation sequencing. We performed an analysis of MinION data derived from whole genome sequencing of Escherichiacoli K-12 using the R9.0 chemistry, comparing the results with the older R7.3 chemistry. METHODS We computed the error-rate estimates for insertions, deletions, and mismatches in MinION reads. RESULTS Run-time characteristics of the flow cell and run scripts for R9.0 were similar to those observed for R7.3 chemistry, but with an 8-fold increase in bases per second (from 30 bps in R7.3 and SQK-MAP005 library preparation, to 250 bps in R9.0) processed by individual nanopores, and less drop-off in yield over time. The 2-dimensional ("2D") N50 read length was unchanged from the prior chemistry. Using the proportion of alignable reads as a measure of base-call accuracy, 99.9% of "pass" template reads from 1-dimensional ("1D") experiments were mappable and ~97% from 2D experiments. The median identity of reads was ~89% for 1D and ~94% for 2D experiments. The total error rate (miscall + insertion + deletion ) decreased for 2D "pass" reads from 9.1% in R7.3 to 7.5% in R9.0 and for template "pass" reads from 26.7% in R7.3 to 14.5% in R9.0. CONCLUSIONS These Phase 2 MinION experiments serve as a baseline by providing estimates for read quality, throughput, and mappability. The datasets further enable the development of bioinformatic tools tailored to the new R9.0 chemistry and the design of novel biological applications for this technology. ABBREVIATIONS K: thousand, Kb: kilobase (one thousand base pairs), M: million, Mb: megabase (one million base pairs), Gb: gigabase (one billion base pairs).
منابع مشابه
MinION Analysis and Reference Consortium: Phase 2 data
Background: Long-read sequencing is rapidly evolving and reshaping the suite of opportunities for genomic analysis. For the MinION in particular, as both the platform and chemistry develop, the user community requires reference data to set performance expectations and maximally exploit third-generation sequencing. We performed an analysis of MinION data derived from whole genome sequencing of K...
متن کاملMinION Analysis and Reference Consortium: Phase 1 data release and analysis
The advent of a miniaturized DNA sequencing device with a high-throughput contextual sequencing capability embodies the next generation of large scale sequencing tools. The MinION™ Access Programme (MAP) was initiated by Oxford Nanopore Technologies™ in April 2014, giving public access to their USB-attached miniature sequencing device. The MinION Analysis and Reference Consortium (MARC) was for...
متن کاملMinION Analysis and Reference Consortium: Phase 1 data
The advent of a miniaturized DNA sequencing device with a high-throughput contextual sequencing capability embodies the next generation of large scale sequencing tools. The MinIONTM Access Programme (MAP) was initiated by Oxford Nanopore TechnologiesTM in April 2014, giving public access to their USB-attached miniature sequencing device. The MinION Analysis and Reference Consortium (MARC) was f...
متن کاملBiodegradation of Polycyclic Aromatic Hydrocarbons (PAHs) in Petroleum Contaminated Soils
Polycyclic aromatic hydrocarbons are a class of potentially hazardous chemicals of environmental and health concern. PAHs are one of the most prevalent groups of contaminants found in soil. Biodegradation of complex hydrocarbon usually requires the cooperation of more than single specie. In this research biotreatment of PAH (phenanthrene) was studied in a solid-phase reactor using indigenou...
متن کاملDesign and Evaluation of Diclofenac Sodium Megaloporous Matrix System Aimed for Colonic Drug Delivery
Megaloporous controlled release tablets of diclofenac sodium (DS) were prepared with two kinds of granules. One of them is the restraining-phase matrix granule (RMG) and it controls the release rate of the drug. The other one is the soluble housing-phase matrix granule (HMG) and controls liquid penetration into the system. Carnauba wax and Eudragit L 100 polymers were used to constitute th...
متن کامل