Chemiluminescence immunoassay: an overview.
نویسندگان
چکیده
A large number of techniques cxist though some arc more suitable than others for the measurement of a particular compound, considerations being given to its size and its concentration. Howcver, all immunoassays require two components, firstly an antibody capable of specifically binding the compound and, secondly, a tracer which permits this binding reaction to be observed. In classical radioimmunoassay (RIA) [ 11 the compound is allowed to react with an antibody, in competition with a radiolabelled antigen analogue for a limited number of antibody binding sites. T h e distribution of radiolabel between antibody bound and free fractions is a measure of the quantity of the compound present. The choice of radiolabel depends upon the compound analysed and may be internal or external. Small molecules usually employ internal labels, for example 3H in steroids and lZsI in thyroid hormones, whereas large molecules invariably utilize an external label, 12'I. Radioiodine has a sensitivity of detection approximately 1000fold that of tritium and is thus universally employed. However, in RIA systems sensitivity is not necessarily limited by the sensitivity of detection of the label but is ultimately dependent upon the equilibrium constant of the antibody-antigen
منابع مشابه
Introducing chemiluminescence resonance energy transfer into immunoassay in a microfluidic format for an improved assay sensitivity.
We report on a novel strategy to improve microfluidic immunoassay sensitivity by introducing chemiluminescence resonance energy transfer (CRET) into the immunoreactions. The proposed CRET-based immunoassay for estradiol (E2, as a model analyte) is one of the most sensitive immunoassay with a limit of detection at 3.6 × 10(-11) M E2 in a microfluidic format.
متن کاملFirst-trimester Combined Screening for Trisomies 21, 18, and 13 by Three Closed Chemiluminescence Immunoassay Analyzers (an Experiment on Iranian Pregnant Women)
Background: Pregnancy-associated plasma protein-A (PAPP-A) and free β-human chorionic gonadotropin (free β-hCG) as valuable biochemical biomarkers are used to screen down syndrome, Edwards syndrome, and Patau syndrome in the first trimester of pregnancy. Closed immunoassay analyzers are regarded as sophisticated platforms to measure biochemical biomarkers. This study compared the performance of...
متن کاملPreparation of an Acridinium Ester-Labeled Antibody and Its Application in GoldMag Nanoparticle-Based, Ultrasensitive Chemiluminescence Immunoassay for the Detection of Human Epididymis Protein 4
An ultrasensitive and rapid sandwich-type chemiluminescence immunoassay (CLIA) was developed for the clinical determination of human epididymis protein 4 (HE4) in human serum, using GoldMag nanoparticles as solid phase and acridinium ester (AE) as chemiluminescence system (GMP-CLIA). The process of AE labeling antibodies was systematically studied and evaluated. The effect of varies factors suc...
متن کاملProtein-enhanced fluorescein chemiluminescence used in an immunoassay for rubella antibody in serum.
The chemiluminescence of fluorescein derivatives is greatly enhanced when they are conjugated to proteins. We exploited this property in devising a chemiluminescence immunoassay for rubella antibodies. In this sequential "sandwich"-type assay, tubes coated with rubella antigen are used for antibody separation and goat antibody to human IgG conjugated with fluorescein isothiocyanate is used for ...
متن کاملEnzyme Immunoassay for the Quantitative Determination of TESTOSTERONE in Human Serum or plasma INTRODUCTION OF CHEMILUMINESCENCE IMMUNOASSAY
متن کامل
Chemiluminescence immunoassay
The use of chemiluininescent molecules as non—isotopic alternatives to 125 in immunoassay permits the development of sensitive, stable assay systems.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 70 5 شماره
صفحات -
تاریخ انتشار 1986