OBJECTIVE In developing countries, tibial shaft fractures are frequently stabilised using Surgical Implant Generation Network (SIGN) nails. Despite widespread use throughout the world, little is known regarding their biomechanical properties. This study aimed to compare the mechanical stiffness of the SIGN tibial nail with a standard hollow tibial nail. METHODS A fracture gap model was created to simulate a comminuted mid-shaft tibia fracture (AO/OTA42-C3) using synthetic composite bones. The constructs were stabilised with either a 9 mm solid SIGN nail or a 10 mm hollow Russell-Taylor nail. Both nail systems were interlocked proximally and distally. Following fixation, the specimens were loaded in axial, torsional, and cyclical axial modes to calculate construct stiffness and irreversible (plastic) deformation. RESULTS The mean axial stiffness for the SIGN nail constructs was 47% higher than mean stiffness for the RT nail constructs (p<0.001). The difference in torsional stiffness was not statistically significant. However, the SIGN group demonstrated 159% more irreversible deformation than the Russell-Taylor group (p=0.006) for the loading parameters studied. CONCLUSION The SIGN tibial nail, despite its slightly smaller diameter, can provide similar construct stiffness and stability, when compared to a larger hollow nail for stabilisation of tibial shaft fractures.
منابع مشابه
Biomechanical Evaluation of the Surgical Implant Generation Network (SIGN) Intramedullary Tibial Nail
INTRODUCTION: The orthopaedic community has become increasingly cognizant of the disparity that exists in healthcare throughout the developing world. Annually, there are nearly five million deaths worldwide due to traumatic injuries; a number approximating that of HIV/AIDS, malaria and tuberculosis combined. Motor vehicle trauma accounts for a large proportion of these deaths, and for every dea...
متن کاملOutcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.
OBJECTIVE To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). STUDY DESIGN Case series. PLACE AND DURATION OF STUDY Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, fr...
متن کاملOutcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملLow infection rates after 34,361 intramedullary nail operations in 55 low- and middle-income countries
BACKGROUND The Surgical Implant Generation Network (SIGN) supplies intramedullary (IM) nails for the treatment of long bone fractures free of charge to hospitals in low- and middle-income countries (LMICs). Most operations are reported to the SIGN Online Surgical Database (SOSD). Follow-up has been reported to be low, however. We wanted to examine the pattern of follow-up and to assess whether ...
متن کاملFemoral fracture fixation in developing countries: an evaluation of the Surgical Implant Generation Network (SIGN) intramedullary nail.
BACKGROUND The Surgical Implant Generation Network (SIGN) intramedullary nailing system was designed to treat femoral fractures in developing countries where real-time imaging, power equipment, and fracture tables are often not available. We performed a retrospective analysis of prospectively collected data on femoral shaft fractures treated with the SIGN intramedullary nailing system. METHOD...