Effect of soft contact lenses on optical measurements of axial length and keratometry for biometry in eyes with corneal irregularities.
نویسندگان
چکیده
PURPOSE To assess the repeatability and reliability of IOLMaster (Carl Zeiss Meditec, Inc., Dublin, CA) axial length and keratometry measurements (K readings) with a soft contact lens on normal eyes. The method is designed for eyes with corneal irregularities or after endothelial keratoplasty. METHODS Biometry was performed on 20 healthy right eyes of volunteer subjects with mean age, 27.3 +/- 4.9 years; axial length, 24.77 +/- 1.04 mm; and K reading, 43.48 +/- 1.69 D. Axial length and keratometry were measured and repeated with -0.5 D SofLens38 (Bausch & Lomb, Rochester, NY) and Acuvue2 (Johnson & Johnson, New Brunswick, NJ) soft contact lenses. Repeatability and reliability were evaluated. Contact lens thickness was measured directly by corneal optical coherence tomography (OCT). RESULTS Axial lengths increased 59 +/- 10 microm with SofLens38 and 134 +/- 13 microm with Acuvue2, and these changes correlated with the OCT contact lens thicknesses (P = 0.995). The axial length variability remained constant (P = 0.18), measuring 24 +/- 10 microm for SofLens38 and 23 +/- 8 microm for Acuvue2 compared with 20 +/- 7 microm with no lens. K readings of 43.08 +/- 1.66 D with SofLens38, 42.79 +/- 1.57 D with Acuvue2, and 43.48 +/- 1.69 D with no lens corresponded to differences of -0.40 +/- 0.12 D with SofLens38 and -0.69 +/- 0.19 D with Acuvue2. The K-reading variability increased slightly from 0.04 to 0.09 D with either lens. CONCLUSIONS Low-power soft contact lenses enable reliable and repeatable IOLMaster axial length and K-reading measurements. Correcting for the measurable lens thickness and lens effects, a <0.5-D error in the Sanders-Retzlaff-Kraff (SRK) II power formula is predicted.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملThe Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure
Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...
متن کاملOptical biometry before and after excimer laser epithelial keratomileusis (LASEK) for myopia.
PURPOSE In order to select the correct intraocular lens (IOL) for implantation, it is important to measure the eye length (biometry). The IOL Master from Zeiss-Humphry is frequently used for such measurements. Because this instrument employs an optical method, any irregularities on the corneal surface or any disturbances in corneal transparency could lead to mistakes in the measurements. The ai...
متن کاملA randomized trial of the effects of rigid contact lenses on myopia progression.
OBJECTIVE To compare the effects of rigid gas-permeable contact lenses (RGPs) and soft contact lenses (SCLs) on myopia progression in children. METHODS We randomly assigned 116 subjects to wear RGPs or SCLs. Subjects underwent cycloplegic autorefraction, keratometry, and A-scan ultrasonographic axial length measurements at each annual visit. All analyses were conducted according to the origin...
متن کاملComparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography
Purpose To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Methods Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 49 8 شماره
صفحات -
تاریخ انتشار 2008