Simulation and Analysis of Cascaded H-Bridge Multilevel Inverter using Single DC source
نویسندگان
چکیده
Cascaded H-Bridge multilevel inverter is a promising topology and provides alternative way for converters that are used in grid connected photovoltaic, wind power generation and in motor drive. Output power can be expanded simply with modularity and control. Though it has wide application area and tremendous merits, it has greater disadvantage that it uses separate DC supply for each HBridge. CMI with single phase transformer and single DC source is proposed for ensure high quality output power waveform. Compared to conventional topology of CMI, proposed topology provides minimization in cost in terms of THD, losses and filter size. Switching angles are calculated for Selective harmonic elimination techniques. Newton– Raphson’s method is used to solve non-linear equations of the system.
منابع مشابه
Transformer-based Single-source Multilevel Inverter with Reduction in Number of Transformers
Single-source binary hybrid multilevel inverters with cascaded transformers have a bulky transformer connected to their main H-bridge cells in each phase. This bulky transformer has been eliminated in this work without any effect on operation and modulation strategies. The proposed topology has significant advantages from view point of dimensions and number of transformers, design of transforme...
متن کاملNew Hybrid Cascaded Multilevel Inverter
This paper proposes a single-phase five-level inverter with a modified pulse width-modulated (PWM)control scheme. The modified pulse width-modulation technique is developed to reduce switching loss.Also, the proposed multilevel inverter can reduce the requirement of power switches compared to aconventional cascaded multilevel inverter. The modes of operation, control signals, and operatingprinc...
متن کاملSimulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter
This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals. In this work multicarrier sinusoidal pulse modulation control methods of Phase disposition (PD-P...
متن کاملDynamic Compensation of Electrical Power Systems Using Multilevel Voltage Source Inverter
A New Static Var Generator (SVG), using cascaded full-bridge inverters (FBI) with binary output levels and the parallel connections of two cascaded inverters by means of current sharing reactor in each phases is introduced. The new M-level inverter, where M is 2n+2 - 3, consists of only 2n single-phase full bridges for each phases. The proposed technique not only increases the current capacity ...
متن کاملSingle Dc Source Cascaded H-bridge Multilevel Inverter Using Three Phase Transformers for Three Phase Applications
This paper proposes an H-Bridge Cascaded Three phase Multilevel Inverter. The proposed three phase Cascaded Multilevel Inverter makes use of single DC source. The proposed three phase Multilevel Inverter uses series connected three phase transformers so the number of single phase transformers used in traditional three phase Multilevel Inverter can be reduced. Hence the volume of the circuit is ...
متن کاملModular Multilevel Current Source Inverter Using Two-Switch Basic Units
This article is an introduction of a new topology of current source inverter (CSI) which can be alternatively implemented in low/medium power applications. This configuration is organized from series connected sub-multilevel inverters blocks. The basis of the recommended multilevel topology is the connections of many cell units in a decent scheme with the help of H-bridge inverter. The suggeste...
متن کامل