On-line Monitoring System based on Vibration Signal of High Voltage Circuit Breaker
نویسندگان
چکیده
High voltage circuit breaker is one of the most important switch apparatus in electrical power system. It play a role in the switch control, which can be used to switch the operating mode during normal operation (the equipment run or quit). In order to ensure the normal operation of the grid, it can be removed quickly when a malfunction on the device or circuit. Real-time online monitoring of high voltage circuit breaker can understand the running status, master the operation characteristics and its tend of development. As early as possible find the potential faults then take preventive measures timely, so as to ensure the reliable operation of power system. Online monitoring of high voltage circuit breakers can reduce the premature or unnecessary maintenance and maintenance cost, improve pertinence of the maintenance firstly. Secondly, it can improve the life of the switching device and improve the reliability of electric power system significantly. In this paper, on-line monitoring system based on vibration signal of high voltage circuit breaker is presented.
منابع مشابه
Development of an Overall Condition Monitoring System of High Voltage SF6 Circuit Breaker
With the rapid development of arts of sensors and IT, on-line monitoring of circuit breaker is now desirable and practical for electric power utilities. This paper describes a set of overall on-line monitoring systems that was developed to control and monitor the condition of SF6 circuit breaker with different type of sensors and microcomputer based controller. The aim of the developed system i...
متن کاملHigh-Voltage Circuit-Breaker Fault Diagnosis Based on Mechanical Vibration Signals
In order to guarantee the operation stability of high-voltage circuit-breaker, this paper extracts eigenvector of vibration signals based on mining of characteristic entropy of the wavelet packet obtained under the state of circuit breaker. Besides, the eigenvector of various fault samples is adopted as the input information of the BP network. After that, the author conducts training of the wel...
متن کاملFault location and classification in non-homogeneous transmission line utilizing breaker transients
In this paper, a single-ended fault location method is presented based on a circuit breaker operation using the frequencies of traveling waves. The proposed method receives the required data from voltage traveling waves with the aid of Fast Fourier Transform (FFT) and Wavelet Transform. Then, the Artificial Neural Network (ANN) identifies fault type and determines its location. In order to eval...
متن کاملSpectroscopic On-Line Monitoring of Cu/W Contacts Erosion in HVCBs Using Optical-Fibre Based Sensor and Chromatic Methodology
Contact erosion is one of the most crucial factors affecting the electrical service lifetime of high-voltage circuit breakers (HVCBs). On-line monitoring the contacts' erosion degree is increasingly in demand for the sake of condition based maintenance to guarantee the functional operation of HVCBs. A spectroscopic monitoring system has been designed based upon a commercial 245 kV/40 kA S F 6 l...
متن کاملApplying Energy-Equal Entropy of Wavelet Packet to Diagnose Circuit Breaker Faults
Aiming to better reflect features of machinery vibration signals of high-voltage HV circuit breaker (CB), a new method is proposed on the basis of energy-equal entropy of wavelet packet(WP). First of all, three-layer wavelet packet decomposes vibration signal, reconstructing 8 nodes of signals in the 3rd layer. Then, the vector is extracted with energy-equal entropy of reconstructed signals. At...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Multimedia
دوره 9 شماره
صفحات -
تاریخ انتشار 2014