Neural-network based autocontouring algorithm for intrafractional lung-tumor tracking using Linac-MR.

نویسندگان

  • Jihyun Yun
  • Eugene Yip
  • Zsolt Gabos
  • Keith Wachowicz
  • Satyapal Rathee
  • B G Fallone
چکیده

PURPOSE To develop a neural-network based autocontouring algorithm for intrafractional lung-tumor tracking using Linac-MR and evaluate its performance with phantom and in-vivo MR images. METHODS An autocontouring algorithm was developed to determine both the shape and position of a lung tumor from each intrafractional MR image. A pulse-coupled neural network was implemented in the algorithm for contrast improvement of the tumor region. Prior to treatment, to initiate the algorithm, an expert user needs to contour the tumor and its maximum anticipated range of motion in pretreatment MR images. During treatment, however, the algorithm processes each intrafractional MR image and automatically generates a tumor contour without further user input. The algorithm is designed to produce a tumor contour that is the most similar to the expert's manual one. To evaluate the autocontouring algorithm in the author's Linac-MR environment which utilizes a 0.5 T MRI, a motion phantom and four lung cancer patients were imaged with 3 T MRI during normal breathing, and the image noise was degraded to reflect the image noise at 0.5 T. Each of the pseudo-0.5 T images was autocontoured using the author's algorithm. In each test image, the Dice similarity index (DSI) and Hausdorff distance (HD) between the expert's manual contour and the algorithm generated contour were calculated, and their centroid positions were compared (Δd centroid). RESULTS The algorithm successfully contoured the shape of a moving tumor from dynamic MR images acquired every 275 ms. From the phantom study, mean DSI of 0.95-0.96, mean HD of 2.61-2.82 mm, and mean Δd centroid of 0.68-0.93 mm were achieved. From the in-vivo study, the author's algorithm achieved mean DSI of 0.87-0.92, mean HD of 3.12-4.35 mm, as well as Δd centroid of 1.03-1.35 mm. Autocontouring speed was less than 20 ms for each image. CONCLUSIONS The authors have developed and evaluated a lung tumor autocontouring algorithm for intrafractional tumor tracking using Linac-MR. The autocontouring performance in the Linac-MR environment was evaluated using phantom and in-vivo MR images. From the in-vivo study, the author's algorithm achieved 87%-92% of contouring agreement and centroid tracking accuracy of 1.03-1.35 mm. These results demonstrate the feasibility of lung tumor autocontouring in the author's laboratory's Linac-MR environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An artificial neural network (ANN)-based lung-tumor motion predictor for intrafractional MR tumor tracking.

PURPOSE To address practical issues of implementing artificial neural networks (ANN) for lung-tumor motion prediction in MRI-based intrafractional lung-tumor tracking. METHODS A feedforward four-layered ANN structure is used to predict future tumor positions. A back-propagation algorithm is used for ANN learning. Adaptive learning is incorporated by continuously updating weights and learning ...

متن کامل

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...

متن کامل

Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy

Background: The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy technique, it is possible to increase the accuracy of delivered dose to the tumor region by means of tracing markers on the body of patients.Objective: This study evaluates the accuracy ...

متن کامل

MRI-guided tumor tracking in lung cancer radiotherapy.

Precise tracking of lung tumor motion during treatment delivery still represents a challenge in radiation therapy. Prototypes of MRI-linac hybrid systems are being created which have the potential of ionization-free real-time imaging of the tumor. This study evaluates the performance of lung tumor tracking algorithms in cine-MRI sagittal images from five healthy volunteers. Visible vascular str...

متن کامل

Design of an Intelligent Controller for Station Keeping, Attitude Control, and Path Tracking of a Quadrotor Using Recursive Neural Networks

During recent years there has been growing interest in unmanned aerial vehicles (UAVs). Moreover, the necessity to control and navigate these vehicles has attracted much attention from researchers in this field. This is mostly due to the fact that the interactions between turbulent airflows apply complex aerodynamic forces to the system. Since the dynamics of a quadrotor are non-linear and the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 42 5  شماره 

صفحات  -

تاریخ انتشار 2015