Light-emitting diode with various sputum smear preparation techniques to diagnose tuberculosis.

نویسندگان

  • M Habtamu
  • J van den Boogaard
  • A Ndaro
  • R Buretta
  • C F Irongo
  • D A Lega
  • B M Nyombi
  • G S Kibiki
چکیده

SETTING Mawenzi Regional Hospital, northern Tanzania. OBJECTIVE To determine the value of light-emitting diode (LED) microscopy in diagnosing tuberculosis (TB) on bleach-treated and direct sputum smears. DESIGN Sputum samples were collected from patients suspected of pulmonary TB who presented consecutively at the laboratory for smear evaluation between December 2009 and February 2010. Four smears were prepared from each specimen: conventional Ziehl-Neelsen (ZN), direct auramine, bleach centrifugation and bleach short sedimentation auramine smears. A light microscope was used to examine ZN smears and an LED fluorescent microscope to examine auramine-stained smears. RESULTS Of the 267 sputum samples examined, respectively 78 (29%), 62 (23%), 74 (28%) and 48 (18%) were acid-fast bacilli (AFB) positive by the bleach centrifugation, bleach short sedimentation, direct auramine and ZN methods. Bleach centrifugation identified 30 (11%) more positives than ZN microscopy (P < 0.001), but was not superior to the direct auramine method (P = 0.46), which yielded 26 (10%) more positives than ZN microscopy (P < 0.001). Fluorescent LED required a shorter smear reading time (1.5 min on average), while the light microscope took 4 min (P < 0.001). CONCLUSION Fluorescent LED microscopy with direct smear preparation is rapid and effective. Further studies are needed to ascertain its performance under routine conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of a streamlined tuberculosis diagnosis and treatment initiation strategy

OBJECTIVE To assess the feasibility of a streamlined strategy for improving tuberculosis (TB) diagnostic evaluation and treatment initiation among patients with presumed TB. DESIGN Single-arm interventional pilot study at five primary care health centers of a streamlined, SIngle-saMPLE (SIMPLE) TB diagnostic evaluation strategy: 1) examination of two smear results from a single spot sputum sp...

متن کامل

LED fluorescence microscopy for diagnosis of tuberculosis in countries with high disease burden

Sputum light microscopy is still the cornerstone of tuberculosis (TB) diagnosis in developing countries. The advent of fluorescence microscope (FM) was a major step forward in the direction of improved diagnosis of TB. But the high cost of the mercury lamp and its maintenance cost gave way to a cheaper alternative, i.e. light-emitting diode (LED). Thus, increased sensitivity, low cost and more ...

متن کامل

Usefulness of light emitting diode (LED) fluorescent microscopy as a tool for rapid and effective method for the diagnosis of pulmonary tuberculosis.

BACKGROUND Tuberculosis remains world's leading cause of death from a single infectious agent. Fluorescence microscopy offers well-described benefits, comparing with brightfield microscopy, for the evaluation sputum smear samples for tuberculosis. We evaluated the diagnostic performance of fluorescence microscopy, using novel Light Emitting Diode (LED) technology as an alternative to the conven...

متن کامل

Staining techniques for detection of acid fast bacilli: what hope does fluorescein-diacetate (FDA) vitality staining technique represent for the monitoring of tuberculosis treatment in resource limited settings

Despite the recent development of more sensitive technologies, diagnosis of tuberculosis in resource limited settings continues to rely on sputum smear microscopy. This is explained by the fact that smear microscopy is simple, inexpensive, and the most accessible tool in resource limited settings for tuberculosis diagnosis. Hot Ziehl-Neelsen (Z-N) is still used in laboratories of resource limit...

متن کامل

LED-Fluorescence Microscopy for Diagnosis of Pulmonary Tuberculosis under Programmatic Conditions in India

BACKGROUND Light-emitting diode fluorescence microscopy (LED-FM) has been shown to be more sensitive than conventional bright field microscopy using Ziehl-Neelsen (ZN) stain in detecting sputum smear positive tuberculosis in controlled laboratory conditions. In 2012, Auramine O staining based LED-FM replaced conventional ZN microscopy in 200 designated microscopy centres (DMC) of medical colleg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2012