Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial.
نویسندگان
چکیده
OBJECTIVE This multi-center, randomized, double-blind, phase 3 trial was conducted to compare the safety and efficacy of contrast agents iohexol-380 and iohexol-350 for coronary CT angiography in healthy subjects. MATERIALS AND METHODS Volunteers were randomized to receive 420 mgI/kg of either iohexol-350 or iohexol-380 using a flow rate of 4 mL/sec. All adverse events were recorded. Two blinded readers independently reviewed the CT images and conflicting results were resolved by a third reader. Luminal attenuations (ascending aorta, left main coronary artery, and left ventricle) in Hounsfield units (HUs) and image quality on a 4-point scale were calculated. RESULTS A total of 225 subjects were given contrast media (115 with iohexol-380 and 110 with iohexol-350). There was no difference in number of adverse drug reactions between groups: 75 events in 56 (48.7%) of 115 subjects in the iohexol-380 group vs. 74 events in 51 (46.4%) of 110 subjects in the iohexol-350 group (p = 0.690). No severe adverse drug reactions were recorded. Neither group showed an increase in serum creatinine. Significant differences in mean density between the groups was found in the ascending aorta: 375.8 ± 71.4 HU with iohexol-380 vs. 356.3 ± 61.5 HU with iohexol-350 (p = 0.030). No significant differences in image quality scores between both groups were observed for all three anatomic evaluations (all, p > 0.05). CONCLUSION Iohexol-380 provides improved enhancement of the ascending aorta and similar attenuation of the coronary arteries without any increase in adverse drug reactions, as compared with iohexol-350 using an identical amount of total iodine.
منابع مشابه
Comparative trial of iohexol 350, a non-ionic contrast medium, with diatrizoate (Urografin 370) in left ventriculography and coronary arteriography.
In a prospective double blind randomised study in 25 consecutive patients a conventional ionic contrast medium (Urografin 370) was compared with the new non-ionic medium iohexol 350 ( Omnipaque ) in left ventriculography and coronary arteriography. In left ventriculography there was a clear patient preference for iohexol by both a visual analogue scale and independent observer assessment. Iohex...
متن کاملIodixanol, a new isosmotic nonionic contrast agent compared with iohexol in cardiac angiography.
Iodixanol, a new ratio 6 nonionic iodinated contrast agent with an osmolality equal to serum, was compared with iohexol in a randomized, double-blind, parallel study. Two hundred patients undergoing elective diagnostic cardiac angiography were randomized to iodixanol (n = 101) or iohexol (n = 99). There were no differences noted between the 2 agents in the mean changes in systolic or diastolic ...
متن کاملOmnipaque vs. Hexabrix in intravenous DSA of the carotid arteries: randomized double-blind crossover study.
A randomized double-blind crossover study using Omnipaque 350 mg l/ml (iohexol) and Hexabrix 320 mg l/ml (ioxaglate) in 53 patients undergoing intravenous digital subtraction angiography of the carotid arteries revealed no significant differences in image quality. Some differences were found in subjective side effects that favored Omnipaque. Nausea was reported in four patients after injection ...
متن کاملA comparison of iopamidol and iohexol in cerebral angiography.
Iopamidol and iohexol, the new nonionic low-osmolality contrast agents, have both been shown to be safe, effective, and better tolerated than conventional ionic agents for cerebral angiography. In this randomized, double-blind study involving 40 patients, these two agents were compared for adverse effects, radiographic quality, and patient tolerance. No significant differences were observed in ...
متن کاملIodixanol Has a Favourable Fibrinolytic Profile Compared to Iohexol in Cardiac Patients Undergoing Elective Angiography: A Double-Blind, Randomized, Parallel Group Study
BACKGROUND There is no consensus and a limited evidence base for choice of contrast agents (CA) in angiography. This study evaluated the impact of iohexol and iodixanol CA on fibrinolytic factors (tissue plasminogen activator [t-PA] and plasminogen activator inhibitor-1 [PAI-1]), as well as platelet-monocyte conjugates in cardiac patients undergoing elective angiography in a double-blind, rando...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Korean journal of radiology
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2016