64-channel Radio Frequency Head Coil Simulations

نویسندگان

  • Anthony Fischetti
  • Tamer Ibrahim
  • Tales Santini
  • Sossena Wood
چکیده

INTRODUCTION Currently with 7 tesla (T) and other ultra-high-field magnetic resonance imaging (MRI), the B1 magnetic fields have a high degree of inhomogeneity with stock MRI configuration. B1 inhomogeneity can lead to the creation of artifacts in the medical image and result in misdiagnosis of medical ailments [1]. Along with artifacts, distortions of both the geometry and intensity of the resulting medical image can occur and further diminish the coverage of the MRI system and therefore reduces the quality of the medical examination [2]. To combat the B1 inhomogeneity experienced with many ultra-high-field MRIs, researcher have created radio frequency (RF) coils to homogenize the magnetic fields emitted from the machine. The basis of an RF coil is to match the same Larmor frequency as the incoming RF source. The coil is tuned and then set to resonate at that specific frequency through the use of capacitive and inductive components [2]. After implementing an RF coil, the resulting image quality is significantly improved and therefore many researchers have explored coils that include loops, plates, and birdcage designs [2]. Another large problem with ultra-high-field MRI is the energy emitted into the patient during the scan, which is measured as specific absorption rate (SAR). The energy distribution inside the subject is extremely subject dependent and non-uniform. Depending on the load size from the (magnetic resonance) MR system, the SAR can be higher or lower in localized regions of the brain [3]. Higher SAR values can lead to increased temperature in the affected region and potentially cause irreversible damage to the tissue of the patient. Scanning with the addition of an RF coil may focus the energy into a localized region and further increase the SAR measured in the tissue. Therefore, RF coil designs must be verified for SAR values using Finite-Difference Time Domain (FDTD) simulations. Additionally, by using FDTD simulations, field homogeneity can be calculated and therefore proves to be an excellent verification method prior to the manufacturing of the RF coil. Current MR technologies include a 16-channel TTT head coil that increased field homogeneity and overall coverage. The design of the 16-channel TTT coil is a single row with a copper shield every 90 degrees (forming a square) [4]. With the development of a 64-channel RF head coil, improvements will be made to the 16-channel TTT coil and the issues associated with field inhomogeneities, increased SAR, and low coverage will hopefully be solved. The proposed coil design consists of two rows with 32 channels each row, totaling in 64 channels. Figure 1 represents the proposed double-octagon coil design. Figure 1. Proposed 64-channel double-octagon head coil for 7T imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Towards the Optimum 7T Head RF Coil

G. McKinnon, E. Boskamp GE Medical Systems, Waukesha, WI, United States Introduction Numerical simulations were used in an attempt to find the optimal configuration for a 7T head coil. The high-pass birdcage, the hybrid birdcage, and the TEM resonator were compared. The coil dimensions were kept as similar as possible. Performance was evaluated on the basis of normalized peak E field, SNR and B...

متن کامل

Interference-Aware and Cluster Based Multicast Routing in Multi-Radio Multi-Channel Wireless Mesh Networks

Multicast routing is one of the most important services in Multi Radio Multi Channel (MRMC) Wireless Mesh Networks (WMN). Multicast routing performance in WMNs could be improved by choosing the best routes and the routes that have minimum interference to reach multicast receivers. In this paper we want to address the multicast routing problem for a given channel assignment in WMNs. The channels...

متن کامل

RADIOFREQUENCY COIL DESIGN AND APPLICATION TO MAGNETIC RESONANCE IMAGING AND CONTROL OF MICRO-BEADS by

Radio Frequency coil development, one component of a functioning magnetic resonance imaging (MRI) system, has evolved since the beginning of MRI into a very diverse area. Today for example, transmit and receive coils, volume and surface coils, and single channel and multiple channel coils are all included. Coils are created to fit the particular needs of specific research purposes, taking into ...

متن کامل

B 1 shimming with a standard 2 channel headcoil at 7 T : possibilities & limitations

Purpose: To study the possibilities and limitations of RF phase and amplitude shimming with a standard 2 channel head coil at 7T. Introduction One of the main problems in high field MRI is the reduced SNR and loss in contrast due to inhomogeneous B1 RF transmit fields. Spatial homogeneity is of primary importance for diagnostic imaging. At 3T the homogeneity problem is mainly limited to regions...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017